Description
Product Overview
The Triconex 3401S2 is a high-availability communication interface module designed for mission-critical safety systems within Schneider Electric’s Triconex platform. As part of the Tri-GP (Triple Modular Redundant General Purpose) series, this module enables robust data exchange between TMR (Triple Modular Redundant) safety controllers and external systems. The 3401S2 serves as a gateway for integrating safety instrumented systems (SIS) with distributed control systems (DCS), supporting real-time data synchronization while maintaining SIL 3 integrity as per IEC 61508 standards.
Engineered for continuous operation in extreme environments, the Triconex 3401S2 features triple-channel redundancy across its communication paths. Its dual-redundant Ethernet ports and RS-485 interfaces allow simultaneous connections to multiple control networks, ensuring zero packet loss during failover events. The module’s patented “Cross-Channel Data Validation” technology compares data streams from all three processors, automatically isolating corrupted signals. With non-intrusive diagnostics and hot-swap capabilities, the 3401S2 is indispensable for oil & gas, nuclear, and chemical plants requiring uninterrupted safety system communication.
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | 3401S2 |
| Manufacturer | Triconex (Schneider Electric) |
| Product Type | TMR Communication Interface Module |
| Protocol Support | Modbus TCP, OPC UA, TriStation Protocol |
| Ethernet Ports | 2x 10/100BASE-TX (redundant) |
| Serial Interfaces | 3x RS-485 (isolated) |
| Data Throughput | 10,000 packets/sec (per channel) |
| Redundancy | Triple Modular Redundant (TMR) |
| Isolation | 1500V AC channel-to-ground |
| Power Supply | 24V DC ±15% (dual redundant inputs) |
| Operating Temperature | -40°C to +85°C |
| MTBF | >120 years (calculated) |
| Certifications | SIL 3, IEC 62443 (Cybersecurity), ATEX |
Key Features Description
The Triconex 3401S2 delivers uncompromised communication reliability through its three independent processing channels. Each channel operates in parallel, with continuous cross-checking via hardware-based voters to ensure data consistency. The module’s “Safe Communication Manager” firmware automatically reroutes traffic during network segmentation, maintaining SIL 3 compliance even during cyber-attack mitigation.
Advanced synchronization capabilities:
Precision time-stamping (±1μs accuracy) across all channels enables deterministic data exchange with DCS systems. The 3401S2 supports simultaneous protocol conversion, allowing legacy Modbus RTU devices to communicate with modern OPC UA architectures without additional gateways. Its embedded firewall filters unauthorized access attempts while permitting authorized safety-critical commands.
The module’s front-panel diagnostic LEDs provide instant status visibility:
- Channel health (green/amber/red)
- Network activity (TX/RX)
- Power supply status
- Voter consensus state
Cybersecurity hardening includes secure boot with cryptographic signature verification and role-based access control. The 3401S2 also features automatic load balancing across redundant networks, optimizing bandwidth usage in large-scale installations.
Application Areas
The Triconex 3401S2 is deployed where safety system integration demands bulletproof communication. In offshore drilling platforms, it synchronizes blowout preventer controls with central monitoring systems. Nuclear power stations utilize its triple redundancy for reactor protection loop communications, while pipeline SCADA systems rely on it for emergency shutdown coordination across remote sites.
Critical implementations include:
- Petrochemical batch reactor sequence synchronization
- LNG terminal fire & gas system integration
- Pharmaceutical cleanroom pressure interlock networks
- Power grid black-start communication backbones
- Aerospace engine test cell safety networks
The module’s extended temperature range (-40°C to +85°C) ensures reliability in desert solar farms and Arctic compressor stations. In hydrogen production facilities, the 3401S2 maintains SIL 3 communication between electrolyzers and safety shutdown systems, while in data centers, it links fire suppression controls with building management systems.
Related Products
- 4351B: Advanced communication module for Tri-GP v11 systems
- 3503E: TMR analog input module
- Tricon v11: Next-gen safety controller chassis
- 9662-810: Dual redundant power supply
- 4000104-510: TriStation 1131 engineering software
- DI3301S2 Tri-GP: Digital input module for safety signals
- 3625X: HART-enabled analog input card
Product Assurance
Schneider Electric provides a 10-year performance guarantee for the Triconex 3401S2, backed by TÜV-certified SIL 3 compliance documentation. Each module undergoes 72-hour burn-in testing with thermal cycling (-55°C to +125°C) and 50g operational vibration tests. The product includes lifetime cybersecurity updates addressing IEC 62443 requirements, with encrypted firmware delivery via secure portals. Global 24/7 support offers 2-hour response commitments for critical infrastructure clients, complemented by on-site training programs for system integrators. The 3401S2 is covered by Schneider’s “Zero Downtime” initiative, providing advance replacement modules for mission-critical installations.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版

Key Features Description