Description
Technical Specifications
| Product Model | EPI3382 |
| Manufacturer | Triconex (Schneider Electric) |
| Product Type | Enhanced Power Interface Module |
| Input Voltage | 24V DC (18-32V range) |
| Output Power | 480W continuous |
| Redundancy | N+1 hot standby |
| Efficiency | 94% at full load |
| Communication | TMRbus protocol |
| Isolation | 3000V AC input-to-output |
| Certifications | SIL 3, IEC 61508, Class I Div 2 |
| Operating Temperature | -40°C to +70°C |
| Warranty | 5 years |
Key Features and Advantages
The EPI3382 delivers fault-tolerant power distribution with triple modular redundancy (TMR) architecture, ensuring uninterrupted operation in critical safety systems. Its active current sharing technology maintains voltage regulation within ±0.5% across parallel modules.
Advanced diagnostics: Features real-time load monitoring with predictive failure alerts through integrated voltage/current sensors. The module’s arc-resistant design prevents energy discharge during hot swapping, complying with NFPA 70E arc flash safety requirements.
Energy efficient operation: Achieves 94% efficiency through zero-voltage switching (ZVS) technology. The conformal coated PCB withstands 98% humidity in harsh environments while maintaining galvanic isolation between input and output circuits.

EPI3382
Application Areas
In offshore drilling platforms, the EPI3382 powers critical safety instrumented systems (SIS) including emergency shutdown valves and gas detection arrays. Its SIL 3 certification ensures compliance with IEC 61511 standards for process safety.
Nuclear power plants utilize this module for reactor protection system power distribution, leveraging its radiation-hardened components. The wide input voltage range (18-32V DC) accommodates unstable grid conditions in remote mining operations.
Chemical processing facilities rely on its Class I Div 2 certification for powering explosion-proof transmitters in hazardous zones. The module’s load sharing capability supports redundant control systems in LNG liquefaction plants.
Related Products
EPI3381: Base model without redundancy features
TMR3382: Triple modular redundant processor module
PSD3320: 20A DC power supply unit
FCM3382: Field communication module
RPM3382: Redundant power monitor
Installation and Maintenance
Installation preparation: Verify proper grounding (<0.1Ω) before connecting the EPI3382. Use 8 AWG minimum copper conductors for power input. Maintain 50mm clearance from high-frequency equipment to prevent EMI interference.
Maintenance recommendations: Perform annual thermal imaging scans on output terminals. Test redundant path failover every 6 months using Triconex diagnostic software. Replace cooling fans at 60,000-hour intervals per MTBF specifications.
Product Assurance
The EPI3382 undergoes MIL-STD-810G vibration testing and 1000-hour burn-in validation. Schneider Electric provides SIL 3 certification packages and safety lifecycle management support. 24/7 critical systems support guarantees 4-hour response with replacement modules shipped in environmentally controlled packaging.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com