Description
Technical Specifications
| Product Model | DI3301 |
| Manufacturer | Triconex (Schneider Electric) |
| Product Type | Digital Input Safety Module |
| Input Channels | 16 isolated channels |
| Input Voltage | 24V DC (18-30V range) |
| Isolation Voltage | 2500V RMS channel-to-system |
| Response Time | ≤1ms |
| Certifications | SIL 3, IEC 61508, ATEX Zone 2 |
| Contact Type | Dry contact/wet input selectable |
| Operating Temperature | -40°C to +70°C |
| Power Consumption | 3.5W typical |
| Warranty | 5 years |
Key Features and Advantages
The DI3301 provides fail-safe digital signal acquisition with triple modular redundancy (TMR) architecture, achieving 99.999% diagnostic coverage for critical safety applications. Its adaptive debounce filtering eliminates contact chatter while maintaining <1ms response for emergency shutdown triggers.
Advanced diagnostics: Features continuous wire-break detection and channel health monitoring through integrated current sensing. The module’s reinforced isolation barriers prevent ground loops in hazardous areas, compliant with ATEX Zone 2 explosion-proof requirements.
Configuration flexibility: Supports both dry contact and 24V wet inputs via software configuration. Hot-swappable design enables module replacement without system downtime, with front-panel LEDs providing instant channel status visualization.

TRICONEX 3301
Application Areas
In chemical processing plants, the DI3301 monitors emergency stop buttons and flame detection sensors, ensuring SIL 3 compliance for process safety systems. Its fast response time (<1ms) meets API 670 requirements for machinery protection in compressor stations.
Nuclear power applications utilize this module for reactor coolant pump status monitoring, leveraging its radiation-hardened components. The wide voltage input range (18-30V DC) ensures reliable operation in substation environments with unstable power supplies.
Offshore oil platforms benefit from its ATEX certification for gas detector inputs in hazardous zones. The module’s moisture-resistant design maintains operation in 98% humidity conditions common in marine environments.
Related Products
AI3301: Analog input module with HART support
DO3301: Digital output module for safety controls
TMR3301X: Triple modular redundant processor
FCM3301: Field communication gateway
PSD3301: Redundant power supply unit
Installation and Maintenance
Installation preparation: Use shielded twisted-pair cables (Belden 8760 or equivalent) for all DI3301 inputs. Maintain 50mm separation from high-voltage cables and ensure proper chassis grounding (<1Ω). Configure input type via TriStation 1131 software before commissioning.
Maintenance recommendations: Perform annual contact resistance measurement on terminal blocks. Clean optical isolation slots every 6 months using approved electronic cleaners. Update firmware during planned shutdowns using Triconex T-1000 programmer.
Product Assurance
The DI3301 undergoes MIL-STD-810G vibration testing and 1000-hour burn-in validation. Schneider Electric provides SIL 3 certification documentation and 24/7 technical support with 4-hour response commitment for critical failures. The 5-year warranty covers all components except damage caused by improper surge protection installation.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版