Description
Technical Specifications
| Product Model | DI3361 |
| Manufacturer | Triconex (Schneider Electric) |
| Product Type | High-Density Digital Input Safety Module |
| Input Channels | 32 isolated channels |
| Input Voltage | 24V DC (18-30V range) |
| Isolation Voltage | 2500V RMS channel-to-system |
| Response Time | ≤500μs |
| Certifications | SIL 3, IEC 61508, ATEX Zone 1 |
| Contact Type | Dry contact/wet input programmable |
| Operating Temperature | -40°C to +85°C |
| Power Consumption | 5.2W typical |
| Warranty | 5 years |
Key Features and Advantages
The DI3361 sets new benchmarks in safety-critical monitoring with quad-redundant processing architecture, achieving 99.999% diagnostic coverage for SIL 3 applications. Its patented transient rejection technology eliminates false triggers from 5kV surge events while maintaining industry-leading 500μs response time.
Advanced channel diagnostics: Features per-point health monitoring with predictive failure analysis through integrated current signature analysis. The module’s reinforced double isolation barriers exceed ATEX Zone 1 requirements for explosive atmospheres, with IP67-rated front connectors for harsh environments.
Smart configuration: Supports group-based parameterization and HART protocol pass-through for intelligent field devices. Hot-swappable design with live insertion detection enables maintenance without process interruption.

2401
Application Areas
In LNG liquefaction plants, the DI3361 monitors cryogenic safety valves and gas detection arrays, providing IEC 61511-compliant protection for SIL 3 loops. Its ultra-fast response prevents escalation of process deviations in fractionation columns.
Nuclear power generation utilizes this module for reactor containment integrity monitoring, leveraging its radiation-hardened components and EMI immunity up to 100V/m. The extended temperature range supports operation in passive cooling systems during station blackouts.
Pharmaceutical batch processes benefit from ATEX Zone 1 certification for solvent handling areas, while the high channel density reduces cabinet space requirements in cleanroom installations.
Related Products
DI3362: 16-channel version with enhanced surge protection
AI3361: 32-channel analog input module
TMR3361X: Triple modular redundant processor
PSD3360: 24V DC redundant power supply
FCM3361: Fieldbus communication gateway
Installation and Maintenance
Installation preparation: Use Belden 9501 shielded twisted pair cables for all DI3361 inputs. Maintain 75mm separation from high-voltage conductors and verify chassis ground integrity (<0.5Ω). Configure input types via Triconex Safety View software before power-up.
Maintenance recommendations: Perform semi-annual dielectric strength tests on isolation barriers. Update firmware annually using Triconex Secure Update Tool. Replace terminal blocks every 7 years or 25,000 insertion cycles.
Product Assurance
The DI3361 undergoes MIL-STD-461F EMI testing and 2000-hour accelerated lifecycle simulation. Schneider Electric provides SIL 3 certification packages and 24/7 critical support with 4-hour response commitment. The 5-year warranty includes free firmware security updates and replacement modules shipped in nitrogen-purged packaging.
Please contact Sunny sales@xiongbagk.cn for the best price.