Honeywell 51400669-100
(Fire Alarm Control Module for Building Safety Systems)
Product Overview
The Honeywell 51400669-100 is a fire alarm control module designed for integration into Honeywell’s NOTIFIER® ONYX® Series fire detection and emergency notification systems. This addressable module enables centralized monitoring and control of fire alarm devices (e.g., smoke detectors, manual pull stations, and notification appliances) in commercial buildings, industrial facilities, and high-rise structures. Compliant with NFPA 72 standards, it ensures rapid response to fire emergencies while minimizing false alarms through advanced signal processing.
Key Features
- Addressable Communication: Supports SLC (Signaling Line Circuit) loops for up to 159 devices per loop.
- Dual Input/Output: Monitors alarm-initiating devices (N.O./N.C. contacts) and controls notification appliances (horns, strobes).
- Diagnostics: Real-time fault detection for open circuits, short circuits, and device tampering.
- Compatibility: Integrates with NOTIFIER® NFS2-3030 and NFS-320 fire alarm control panels (FACPs).
- Certifications: UL 864 listed, EN54-18 certified, and compliant with local fire codes (e.g., IBC, IFC).
Technical Specifications
| Parameter | Details |
|---|---|
| Input Voltage | 24 VDC (16–33 VDC range) |
| Current Draw | 3 mA (standby), 15 mA (alarm) |
| Contact Rating | 2 A @ 30 VDC (resistive) |
| Operating Temp | -10°C to +55°C |
| Humidity | 0–93% non-condensing |
| Enclosure | Metal or plastic (UL-rated for plenum spaces) |
| Dimensions | 102 x 102 x 38 mm (WxHxD) |

51401497-100
Application Areas
- Commercial Buildings: Connects smoke detectors, duct detectors, and manual call points in offices and malls.
- Industrial Plants: Monitors flame detectors and gas sensors in hazardous areas.
- Healthcare: Integrates with nurse call systems and elevator recall in hospitals.
- Transportation Hubs: Controls voice evacuation systems in airports and metro stations.
Installation & Configuration
- Wiring: Use shielded, fire-rated cable (e.g., FPLR) for SLC loops.
- Addressing: Assign a unique SLC address via DIP switches or software (NOTIFIER® VeriFire® Tools).
- Testing: Perform end-to-end loop validation per NFPA 72 requirements.
- Integration: Program alarm sequences and cross-zoning logic in the FACP.
Related Products
- 51400669-200: Upgraded version with extended temperature range (-30°C to +70°C).
- NOTIFIER AFP-3000: Advanced fire alarm panel for large-scale systems.
- Honeywell HWP-1704: Horn/strobe notification appliance compatible with this module.
- FZM-1: Zone monitor module for conventional device integration.
Product Assurance
- Warranty: 3-year limited warranty covering defects in materials and workmanship.
- Compliance: Meets NFPA 72, UL 864, and EN54 standards for fire safety.
- Support: Access Honeywell’s 24/7 Technical Assistance Center for troubleshooting and firmware updates.
Why It Matters
The Honeywell 51400669-100 is critical for ensuring life safety and property protection in complex environments. Its reliability and seamless integration with NOTIFIER® systems make it a cornerstone of modern fire alarm architectures. For detailed configuration guides, refer to Honeywell Document 51400669-100-01 or consult a certified NOTIFIER® distributor.
Please contact Sunny sales@xiongbagk.cn for the best price.