Triconex 3525A | ​digital input module

Triconex 3625A
(Digital Input Module for Safety Instrumented Systems)


Product Overview

The Triconex 3625A is a ​digital input module designed for Schneider Electric’s ​Tricon and ​Trident safety systems. It provides fault-tolerant, high-integrity input processing for critical industrial applications such as emergency shutdown (ESD), fire and gas systems, and turbine control. Compliant with ​IEC 61508 SIL 3 standards, this module ensures reliable monitoring of field devices (e.g., switches, sensors) in oil and gas, chemical, and power generation industries.

Category:

Description

Triconex 3625A
(Digital Input Module for Safety Instrumented Systems)


Product Overview

The Triconex 3625A is a ​digital input module designed for Schneider Electric’s ​Tricon and ​Trident safety systems. It provides fault-tolerant, high-integrity input processing for critical industrial applications such as emergency shutdown (ESD), fire and gas systems, and turbine control. Compliant with ​IEC 61508 SIL 3 standards, this module ensures reliable monitoring of field devices (e.g., switches, sensors) in oil and gas, chemical, and power generation industries.


Key Features

  • Redundant Architecture: Triple Modular Redundant (TMR) design for fault tolerance and voting logic.
  • Input Compatibility:
    • 24 VDC or ​48 VDC dry/wet contact inputs.
    • Supports ​NAMUR sensors for hazardous areas.
  • Diagnostics: Continuous monitoring for open circuits, short circuits, and signal integrity.
  • Hot Swap: Replaceable without system downtime.
  • Certifications: ATEX/IECEx (optional), UL, CE.

Technical Specifications

Parameter Details
Channels 16 digital inputs
Input Voltage 24/48 VDC (configurable)
Isolation 1,500 VAC (channel-to-system)
Response Time ≤10 ms per channel
Power Supply 24 VDC via Tricon chassis
Operating Temp -40°C to +70°C
Enclosure IP20 (rack-mounted) or IP66 (harsh environments)

Application Areas

  • Emergency Shutdown (ESD): Monitors safety switches and pressure sensors in pipelines.
  • Fire & Gas Systems: Detects flame or gas detection alarms.
  • Turbine Protection: Tracks overspeed or vibration trip signals.
  • Process Interlocks: Safeguards reactors and pumps via permissive logic.

Installation & Configuration

  1. Mounting: Installs in a ​Tricon V9/V11 chassis or ​Trident cabinet.
  2. Wiring: Uses shielded cables; terminals support 12–24 AWG.
  3. Programming: Configured via ​TriStation 1131 software for debounce filtering and alarm thresholds.
  4. Testing: Validate with simulated inputs to ensure SIL 3 compliance.

Related Products

  1. Triconex 3626X: Digital output module for actuator control.
  2. Triconex MP3008: Main processor for Tricon CX systems.
  3. Triconex 4351B: Analog input module for SIL 3 applications.
  4. Trident Safety System: Modern platform for next-gen safety logic.

Why It Matters

The ​3625A ensures fail-safe operation by accurately monitoring critical signals in high-risk environments. Its TMR design minimizes spurious trips and guarantees operational continuity, aligning with global safety standards like ​API 670 and ​IEC 61511.


Product Assurance

  • Warranty: 5-year lifecycle support with firmware updates.
  • Compliance: Meets IEC 61508/61511, ANSI/ISA 84, and NAMUR NE 43.
  • Support: Access Schneider Electric’s ​24/7 Critical Care Support for urgent troubleshooting.

For technical details, refer to ​Triconex Manual D042741 or contact Schneider Electric’s ​Process Safety Team. Always validate configurations with ​HAZOP/LOPA studies.

Note: Legacy modules like the 3625A may require migration to ​Tricon CX or ​Trident for enhanced features.