2CCS862001R0105 High performance circuit breaker

Technical
Standards:IEC/EN 60947-2, IEC/EN 60898-1, UL 1077
Tripping Characteristic:B
Type of Residual Current:standard version
Rated Voltage (Ur):acc. to IEC 60947-2 690 V AC
acc. to IEC 60947-2 250 V DC
acc. to IEC 60898-1 400 V AC
Rated Operational Voltage:acc. to IEC 60898-1 400 V
Operational Voltage:Maximum 230/400 V AC
Minimum 12 V AC

Category:

Description

Extended Product Type:S802S-B10
Product ID:2CCS862001R0105
EAN:7612271200121
Catalog Description:S802S-B10 High Performance MCB
Long Description:The S802S-B10 is a 2-pole High Performance Circuit breaker with B-characteristic, with cage terminal and a rated current of 10 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. The S802S-B10 complies with IEC/EN 60898-1 and IEC/EN 60947-2 and allows the use for residential, commercial and industrial applications. It has numerous of approvals, therefore it can be used worldwide. The extensive range of accessory makes the use of S802S-B10 more comfortable. Due to the fast arc extinction of S802S-B10 your application will be secured.

S802S-B10 2CCS862001R0105

Technical
Standards:IEC/EN 60947-2, IEC/EN 60898-1, UL 1077
Tripping Characteristic:B
Type of Residual Current:standard version
Rated Voltage (Ur):acc. to IEC 60947-2 690 V AC
acc. to IEC 60947-2 250 V DC
acc. to IEC 60898-1 400 V AC
Rated Operational Voltage:acc. to IEC 60898-1 400 V
Operational Voltage:Maximum 230/400 V AC
Minimum 12 V AC
Rated Insulation Voltage (Ui):acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (Uimp):8 kV
Input Voltage Type:AC/DC
Rated Current (In):10 A
Rated Operational Current (Ie):10 A
Rated Short-Circuit Capacity:(230 V) 25 kA
(400 V) 25 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):(230 V) 50 kA
(400 V) 6 kA
Rated Conditional Short-Circuit Current (Inc):(230 V) 50 kA
(400 V) 50 kA
Rated Service Short-Circuit Breaking Capacity (Ics):(240 / 415 V AC) 40 kA
(254 / 440 V AC) 22.5 kA
(400 / 690 V AC) 4 kA
(125 V DC) 30 kA

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com