PFCL201CE-50KN Pressductor PillowBlock Load Cells

This manual describes the load cells PFCL 201C/201CE/201CD in a Pressductor® Strip Tension
Measuring System.

Category:

Description

PFCL201CE-50KN Pressductor PillowBlock Load Cells

This manual describes the load cells PFCL 201C/201CE/201CD in a Pressductor® Strip Tension
Measuring System.
The purpose of this manual is to describe the general function and design of the load cells and also
to be a guidance at installation, commissioning, preventive maintenance and fault tracing.

The crossed – out wheeled bin symbol on the product(s) and / or accompanying documents
means that used electrical and electronic equipment (WEEE) should not be mixed with general
household waste.
If you wish to discard electrical and electronic equipment (EEE), in the European Union, please
contact your dealer or supplier for further information.
Outside of the European Union, contact your local authorities or dealer and ask for the correct
method of disposal.
Disposing of this product correctly will help save valuable resources and prevent any potential negative effects on human health and the environment, which could otherwise arise from inappropriate
waste handling.

PFCL201CE-50KN

ABB designs all transport material to be recyclable where practical. The recycling of the transport
material depends on the material type and availability of local recycling programs.
After receiving the system into the site, the package and the transportation locking have to be
removed. Recycle the transport material according to local regulations.

The load cells are installed under the roll bearings, where they measure forces at right angles to the
mounting surface.
The reactive force from the strip, which is proportional to the strip tension, is transferred to the load
cells via the roll and the bearings.
The load cells are connected to the control unit via a junction box. The control unit converts the
load cell signals to DC voltages that are proportional to the reaction force. Depending on which
control unit is chosen, it is possible to have the analog signals for the two individual load cells (A
and B), the sum of the load cell signals (A+B), and/or the difference between the load cell signals
(A-B).