Description
Product Overview
UNS2980 C-Z.V1 (Material No. : HIEE205019R1) is a modular AC contactor from ABB’s UNO series, specifically designed for industrial motor control and power distribution systems. This product adopts a compact modular structure, supports direct plug-in auxiliary contact expansion, and features a high electrical life and shock resistance. It is suitable for heavy-duty scenarios such as frequency converter control, pump equipment, and compressors.
Core features
Feature description
The modular design supports hot-swappable auxiliary contacts (up to 8 groups expandable) and mechanical interlock modules
High-performance arc-extinguishing optimized magnetic blowout arc extinguishing system, with a breaking capacity of up to 100kA (IEC 60947-4-1)
The wide voltage adaptive coil voltage supports 24V DC to 500V AC (C-Z.V1 is a dedicated model for 24V DC).
Resistant to harsh environments, it can withstand 100% relative humidity and salt spray corrosion (in compliance with IEC 60068-2-52)
Safety certification Dual-channel forced disconnection contact (compliant with SIL3/PL e)
Technical Specification Sheet
Parameter category technical indicators
Electrical parameters
Rated working current (Ie) 40A (AC-3, 400V)
Rated insulation voltage (Ui) : 1000V
Breaking capacity: 10×Ie (440V AC)
Coil power consumption: 8W (engaged) / 1.5W (held)
Mechanical properties
Electrical life 1×10⁶ times (AC-3)
Mechanical life: 3×10⁷ times
Contact configuration: Main contact: 3NO; Auxiliary contact: 2NO+2NC (expandable)

UNS2980c-ZV4
Environmental adaptability
Operating temperature: -40°C to +70°C
Protection grade: IP20 (main body)/IP65 (after installing the protective cover)
Anti-vibration: 5-100Hz, amplitude 1.5mm (IEC 60068-2-6)
Installation parameters
Installation method: 35mm DIN rail (EN 60715)
Wiring capacity: Main circuit: 25mm² wire; Control circuit: 2.5mm² wire
Dimensions (W×H×D) : 55mm × 85mm × 75mm
Compatibility of expansion modules
Module type, model example, function description
The auxiliary contact group UNOAX-1 (HIEE205019R2) has added 1NO+1NC contacts
The mechanical interlocking kit UNO-ILK (HIEE205019R3) features dual contactor interlocking to prevent short circuits
Delay module UNO-TM (HIEE205019R4) power-off delay release (adjustable from 0.1 to 30 seconds)
Surge suppressor UNO-RC (HIEE205019R5) coil overvoltage protection (≤2.5kV)
Typical application scenarios
Industry application cases
Motor control for industrial manufacturing injection molding machines (main circuit switching + mechanical interlock)
HVAC system central air conditioning compressor start-stop control (in conjunction with thermal overload relay)
Group rotation control of water treatment pumps (Expand auxiliary contacts to achieve status feedback)
Input side circuit breaker control of renewable energy photovoltaic inverters (surge suppression module for lightning protection)
Installation and wiring instructions
1. Main circuit wiring
Terminal identification: L1/L2/L3 (incoming line), T1/T2/T3 (outgoing line)
Torque requirements: 2.5N·m for the main terminal and 1.2N·m for the control terminal
2. Control loop connection
• Coil terminals: A1 (+24V DC), A2 (-24V DC)
• Auxiliary contacts: 13-14 (NO), 21-22 (NC)
3. Safety distance
• Adjacent installation spacing: ≥10mm (horizontal), ≥25mm (vertical)
Certification and Standards
The scope of application of the certification type standard number
Safety certification IEC/EN 60947-4-1 for low-voltage switchgear
Electromagnetic compatibility EN 61000-6-2/6-4 industrial environment anti-interference
Low-energy consumption coil design in accordance with energy efficiency standard IEC 60470 (CoC V class)
Marine certified DNV-GL/ABS Marine power System (Salt spray resistant version is required as an option)
Precautions
1. Coil voltage matching
• C-Z.V1 is a dedicated model for 24V DC. Incorrect connection to AC power supply will cause the coil to burn out
2. Arc extinguishing protection
For frequent on-off scenarios (> 600 times per hour), arc extinguishing grilles (optional UNO-ARC) need to be installed.
3. Maintenance cycle
It is recommended to check the contact thickness (wear amount < 0.5mm) every 50,000 operations.
4. Fault Diagnosis
• Abnormal noise: Check for fluctuations in power supply voltage (±10% allowed) or mechanical jamming
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版