Description
2094-BC01-M01-S 400 Volt class Integrated Axis Module
The Allen-Bradley 2094-BC01-M01-S is a Kinetix 6000 multi-axis integrated power module that comes
with a safe torque off feature. This 2094-BC01-M01-S Kinetix Drive contains an inverter and converter
section. It comes with a 9 A inverter power and a 6 kW converter power, as well as a wattage of 3.9 kW.
This 3-phase module has a voltage rating of 460V AC and a line frequency of 47-63 Hz. Mounting of the
2094-BC01-M01-S module is done via a power rail. The 2094-BC01-M01-S is a 400 volt-class drive. The
input voltage of this Kinetix 6000 Multi-axis Servo Drive is 360-480V AC. Kinetix 6000 Multi-axis servo
drives are designed to provide Kinetix Integrated Motion for the drive, motor and actuator applications.
The Allen-Bradley 2094-BC01-M01-S is a Kinetix 6000 multi-axis servo module. Specifically, this product
is an integrated axis module that is used to receive feedback signals from compatible servo motors for
conditioning and processing. This drive is compatible for use with a variety of Allen-Bradley drives, whether
Kinetix or non-Kinetix rotary motors, such as Kinetix MP, Kinetix TL/TLY, Kinetix RDB, 1326AB, and the
F-Series. It also supports Linear motors including LDC-Series, LDL-Series and Linear actuators particularly LDAT series.
Through the integrated SERCOS interface, the 2094-BC01-M01-S may be connected in linear or ring
topology using Fiber optic media. This enables high-speed data communication and provides the highest
susceptibility to electrical noise. Additionally, it may be partnered with SERCOS interface modules and cards
such as the 1756-MxxSE ControlLogix SERCOM interface module; 1768-M04SE CompactLogix SERCOS
interface module, and the 1784-PM16SE PCI card SERCOS PCI SoftLogix communication card.
The 2094-BC01-M01-S supports Safe Torque-Off (STO) functionality. This integrated safety feature is
certified at ISO 13849-1 PLe/SIL3. If compliance to EN954-1 Category 3 is needed, an external safety
relay may be needed. The STO’s main functionality is mainly used to prevent drive restart after the safety circuit is tripped.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com