3500/92 136188-01 3500/92 Communication Gateway
values and statuses for integration with process control and other automation systems using both Ethernet TCP/IP and
serial (RS232/RS422/RS485) communications capabilities. It also permits Ethernet communications with 3500 Rack
Configuration Software and Data Acquisition Software. Supported protocols include:
l Modicon Modbus protocol (via serial communications)
l Modbus/TCP protocol (a variant of serial Modbus used for TCP/IP Ethernet communications)
l Proprietary Bently Nevada protocol (for communication with 3500 Rack Configuration and Data Acquisition Software packages)
The 3500/92 supports the communication interfaces, communication protocols, and other features from the
original 3500/90 with the exception of the primary value Modbus registers. The 3500/92 now has a Configurable
Modbus Register Utility, which can provide the same functionality originally addressed by the primary value Modbus registers.
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
l This device may not cause harmful interference.
l This device must accept any interference received, including
interference that may cause undesired operation.
EMC
European Community Directive:
EMC Directive 2014/30/EU
Standards:
EN 61000-6-2; Immunity for Industrial Environments
EN 61000-6-4; Emissions for Industrial Environments
The 3500/92 Communication Gateway module provides extensive
communication capabilities of all rack monitored values and statuses for integration with process control and other automation systems using both
Ethernet TCP/IP and serial (RS232/RS422/RS485) communications capabilities. It
also permits Ethernet communications with 3500 Rack Configuration Software and Data Acquisition Software.
Supported protocols include:
• Modicon® Modbus® protocol (via serial communications)
• Modbus/TCP protocol (a variant of serial Modbus used for TCP/IP
Ethernet communications)
• Proprietary Bently Nevada protocol (for communication with 3500 Rack Configuration and Data Acquisition Software packages)
The Ethernet connection to the 3500/92 is an RJ45 connection for 10BASE-T star configuration Ethernet networks.
The 3500/92 supports the communication interfaces, communication protocols, and other features from the original 3500/90 with the exception of the primary
value Modbus registers. The 3500/92 now has a Configurable Modbus Register Utility, which can provide the same functionality originally addressed by the
primary value Modbus registers.