3500/92 136188-01 3500/92 Communication Gateway

The 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored
values and statuses for integration with process control and other automation systems using both Ethernet TCP/IP and
serial (RS232/RS422/RS485) communications capabilities. It also permits Ethernet communications with 3500 Rack
Configuration Software and Data Acquisition Software. Supported protocols include:
l Modicon Modbus protocol (via serial communications)
l Modbus/TCP protocol (a variant of serial Modbus used for TCP/IP Ethernet communications)
l Proprietary Bently Nevada protocol (for communication with 3500 Rack Configuration and Data Acquisition Software packages)

The 3500/92 supports the communication interfaces, communication protocols, and other features from the
original 3500/90 with the exception of the primary value Modbus registers.

Category:

Description

3500/92 136188-01 3500/92 Communication Gateway

The 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored
values and statuses for integration with process control and other automation systems using both Ethernet TCP/IP and
serial (RS232/RS422/RS485) communications capabilities. It also permits Ethernet communications with 3500 Rack
Configuration Software and Data Acquisition Software. Supported protocols include:
l Modicon Modbus protocol (via serial communications)
l Modbus/TCP protocol (a variant of serial Modbus used for TCP/IP Ethernet communications)
l Proprietary Bently Nevada protocol (for communication with 3500 Rack Configuration and Data Acquisition Software packages)

The 3500/92 supports the communication interfaces, communication protocols, and other features from the
original 3500/90 with the exception of the primary value Modbus registers. The 3500/92 now has a Configurable
Modbus Register Utility, which can provide the same functionality originally addressed by the primary value Modbus registers.

350092-136180-01

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
l This device may not cause harmful interference.
l This device must accept any interference received, including
interference that may cause undesired operation.
EMC
European Community Directive:
EMC Directive 2014/30/EU
Standards:
EN 61000-6-2; Immunity for Industrial Environments
EN 61000-6-4; Emissions for Industrial Environments

The 3500/92 Communication Gateway module provides extensive
communication capabilities of all rack monitored values and statuses for integration with process control and other automation systems using both
Ethernet TCP/IP and serial (RS232/RS422/RS485) communications capabilities. It
also permits Ethernet communications with 3500 Rack Configuration Software and Data Acquisition Software.
Supported protocols include:
• Modicon® Modbus® protocol (via serial communications)
• Modbus/TCP protocol (a variant of serial Modbus used for TCP/IP
Ethernet communications)
• Proprietary Bently Nevada protocol (for communication with 3500 Rack Configuration and Data Acquisition Software packages)
The Ethernet connection to the 3500/92 is an RJ45 connection for 10BASE-T star configuration Ethernet networks.
The 3500/92 supports the communication interfaces, communication protocols, and other features from the original 3500/90 with the exception of the primary
value Modbus registers. The 3500/92 now has a Configurable Modbus Register Utility, which can provide the same functionality originally addressed by the
primary value Modbus registers.

 

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com