51405046-175 CC-PCNT01 Pulse Counter Input Module​

Specification Category Details
​Manufacturer / Series​ Honeywell Experion PKS
​Honeywell Part Number​ ​51405046-175​​ (Assembly Number)
​Hardware Model​ ​CC-PCNT01​
​Module Type​ Pulse Counter / Frequency Input
​Number of Channels​ 8 channels
​Input Types​ Dry Contact (volt-free contact); Logic Level (e.g., 5V, 12V, 24V DC)
​Maximum Count Frequency​ Typically 10 kHz (consult datasheet for specific model)
​Count Resolution​ 32-bit counting for large totalization values
​Power Supply​ Powered by the Experion PKS I/O bus (e.g., 5V DC)
​Isolation​ Channel-to-channel and channel-to-system isolation
​Hot Swap Support​ Yes
​Field Power​ Can provide a wet voltage (e.g., 24V DC) for sourcing transmitters
​Compatible Systems​ Honeywell Experion PKS (with C300 controller or FTE network)
Category:

Description

Honeywell 51405046-175 (CC-PCNT01) Pulse Counter Input Module​

https://example.com/image-cc-pcnt01.jpg ​​Product Overview​​ The Honeywell ​​51405046-175​​, commercially designated as the ​​CC-PCNT01​​, is a high-performance 8-Channel Pulse Counter Input Module for the Experion® PKS (Process Knowledge System) platform. This specialized module is designed to accurately count high-speed digital pulses from field instruments, enabling precise monitoring and control based on pulse-rate or totalized values. It serves as a critical interface for devices that output frequency or pulse signals, translating them into digital data for the control system. The CC-PCNT01 is essential for applications requiring accurate batching, flow totalization, energy metering, or speed monitoring. ​​Key Features​

  • ​High-Speed Counting:​​ Capable of accurately counting high-frequency pulse signals, typically up to 10 kHz or higher, depending on configuration.
  • ​Dual-Function Channels:​​ Each of the 8 channels can be independently configured as a pulse counter (for totalization) or as a frequency input (for rate measurement).
  • ​Advanced Diagnostics:​​ Includes comprehensive self-diagnostics and channel-status monitoring for detecting field wiring faults such as open circuits.
  • ​Flexible Input Types:​​ Supports a wide range of industry-standard pulse input types, including contact closure (dry contact) and voltage pulse (sourcing) signals.
  • ​Hot-Swappable Operation:​​ Supports online insertion and removal, facilitating maintenance without process shutdown to maximize system availability.
  • ​LED Status Indicators:​​ Provides per-channel and module-level LED status indicators for quick visual health and status confirmation.

​Technical Specifications​

Specification Category Details
​Manufacturer / Series​ Honeywell Experion PKS
​Honeywell Part Number​ ​51405046-175​​ (Assembly Number)
​Hardware Model​ ​CC-PCNT01​
​Module Type​ Pulse Counter / Frequency Input
​Number of Channels​ 8 channels
​Input Types​ Dry Contact (volt-free contact); Logic Level (e.g., 5V, 12V, 24V DC)
​Maximum Count Frequency​ Typically 10 kHz (consult datasheet for specific model)
​Count Resolution​ 32-bit counting for large totalization values
​Power Supply​ Powered by the Experion PKS I/O bus (e.g., 5V DC)
​Isolation​ Channel-to-channel and channel-to-system isolation
​Hot Swap Support​ Yes
​Field Power​ Can provide a wet voltage (e.g., 24V DC) for sourcing transmitters
​Compatible Systems​ Honeywell Experion PKS (with C300 controller or FTE network)

​Typical Applications​​ The CC-PCNT01 is used in a wide range of industrial applications for precise measurement and control:

  • ​Flow Totalization:​​ Accurately totalizing flow from pulse-output flowmeters (turbine, vortex, positive displacement) for custody transfer or batch processes.
  • ​Energy Management:​​ Monitoring energy consumption by counting pulses from utility meters (gas, water, electricity).
  • ​Batching & Blending:​​ Controlling the precise amount of material added in batch processes based on counted pulses from scales or flow meters.
  • ​Speed Monitoring:​​ Measuring the rotational speed of motors, turbines, or conveyors using proximity sensors or encoders.

​Configuration & Integration​

  • The module installs into a Honeywell Experion PKS Series A or C I/O Module Assembly.
  • It communicates with a C300 Process Controller or over the Fault Tolerant Ethernet (FTE) network via a Field Bus Interface Module (FBIM).
  • Configuration, including input type (dry contact/logic), debounce filter settings, and scaling, is performed within the ​​Honeywell Control Builder​​ engineering software.

​Disclaimer:​​ This information is for descriptive purposes based on standard product data. Specifications are subject to change by the manufacturer. For critical applications, always consult the official ​​Honeywell Experion PKS documentation and hardware specifications (for CC-PCNT01)​​ for the exact installation, configuration, and safety procedures. Configuration and installation should be performed by qualified personnel.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com