Description
781346-01 PXIE-4330 high-performance PXI Express strain/bridge input module
Product Description
The PXIE-4330 is a high-performance PXI Express strain/bridge input module from National Instruments (NI). Here are some detailed product details about the PXIE-4330:
Functions and Applications:
The PXIE-4330 is designed for high-performance strain, load, force value and moment measurement.
It is capable of automatic, simultaneous measurements of quarter, half and full Bridges, and is particularly suitable for test applications requiring high channel count architectures, such as wind tunnels, bridge inspection and crash testing.
Technical specifications:
Accuracy: Up to 0.02%, providing high precision measurement.
Sampling rate: Up to 25kS/s (25,000 samples/second) per channel, supporting high-speed data acquisition.
Input channels: Typically has 8 analog input channels that can be scaled up to 136 channel systems in a single chassis and thousands of channels when synchronized across multiple chassis.
Input range: Multiple bridge resistors and voltage ranges are supported, such as -25 mV/V to 25 mV/V and -100 mV/V to 100 mV/V.
Bridge design: The proportional design makes the ADC chip reference to the excitation voltage, and no longer depends on the stability and accuracy of the excitation voltage.
Synchronization and calibration:
The PXIE-4330 supports simultaneous measurement of multiple modules and chassis, and can achieve inter-channel skew errors as low as 5ppb through the included driver software.
Each channel can be configured entirely via software for bridge measurement or direct voltage measurement.
Extensibility:
In addition to the strain/bridge input function, it can be used in combination with other NI modules, such as the NI PXIe-4353 thermocouple module, to meet a wider range of measurement needs.
Software support:
Support NI’s LabVIEW and other data acquisition and analysis software to facilitate data acquisition, processing and analysis.
Physical characteristics:
The PXI Express slot size is usually used, and the standard PXI Express chassis is supported.
The module design is compact and suitable for integration into various test systems.

PXIE-4330
Product parameter
The PXIe-4330 is a PXI strain/bridge input module from National Instruments (NI) whose parameters may include:
Model: PXIe-4330
Number of channels: Typically has 8 analog input channels, supporting simultaneous measurement of multiple modules and chassis.
Maximum sampling rate: Up to 25kS/s (25,000 samples/second) per channel, which may vary depending on configuration and measurement mode.
Bridge resistance: Support a variety of bridge resistance, such as 120 ohms, 1000 ohms, 350 ohms and so on.
Analog input voltage range: Voltage ranges from -25 mV/V to 25 mV/V and -100 mV/V to 100 mV/V are supported, depending on bridge configuration.
Bridge configuration: Full-bridge, half-bridge, and quarter-bridge configurations are supported.
Accuracy: Depending on the specific configuration and measurement conditions, accuracy may vary, but usually a higher level of accuracy can be achieved.
Synchronization: Supports simultaneous measurement of multiple modules and chassis, enabling skew errors between channels as low as 5ppb.
Physical features: PXI Express slot size, suitable for standard PXI Express chassis.
Application field
The PXIe-4330 is a PXI strain/bridge input module from National Instruments (NI) for a wide range of applications. Here are some typical application areas:
Structural Health Monitoring: In structural health monitoring of Bridges, buildings, tunnels and other large infrastructure, the PXIe-4330 can be used to measure strain, load and force values to assess structural integrity and safety.
Materials testing: In materials science research, the PXIe-4330 can be used to measure the strain and deformation of materials under different loads, helping researchers understand the mechanical properties and behavior of materials.
Aerospace: In the aerospace sector, the PXIe-4330 can be used for load and structure monitoring of aircraft, rockets and other aircraft. By taking real-time strain measurements of aircraft structures in flight, their structural integrity and safety can be assessed.
Automotive Engineering: In the field of automotive engineering, the PXIe-4330 can be used for vehicle crash testing, chassis and suspension system testing, etc. By measuring the strain and load of the vehicle under different conditions, the performance and safety of the vehicle can be assessed.
Energy and power: In the field of energy and power, the PXIe-4330 can be used for monitoring and testing of wind turbines, turbines and other equipment. By measuring the strain and load of the equipment, its operating state and life can be assessed.
Education and Research: In the field of education and research, the PXIe-4330 can be used in a variety of experiments and projects to help students and researchers understand the basic principles and methods of strain measurement and data analysis.
In short, the PXIe-4330’s high precision, high reliability and multi-channel synchronous measurement capabilities make it ideal for a variety of applications requiring strain and load measurement. Whether in structural health monitoring, material testing or aerospace and automotive engineering, the PXIe-4330 provides accurate and reliable measurement data to support research and development.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797