SCXI-1102C Voltage Input Module SCXI-1104C

National Instruments SCXI-1102C Voltage Input Module

The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. This Voltage Input Module is designed for the signal conditioning of thermocouples, low-bandwidth volt and millivolt sources, 4 to 20 mA current sources, and 0 to 20 mA process-current sources. The NI SCXI-1102C can perform these measurements: current input, thermistors, voltage input, RTD, and thermocouple. It has a power requirement of 15 mA maximum at 5 V, and 150 mA maximum at ±15 V.

Category:

Description

SCXI-1102C Voltage Input Module SCXI-1104C

Product Description

Specifications: Specific physical dimensions may include 26 units of length, 33 units of width and 37 units of height.
Design:
Modular design: The SCXI-1102C uses a modular design that allows users to insert different data acquisition cards to achieve a variety of data acquisition functions. This design makes the chassis highly flexible and customizable.
Easy to use: The chassis features an intuitive user interface and easy-to-use software for easy configuration, operation, and management.
Features:
High performance: The SCXI-1102C has high-speed data acquisition and transmission capabilities, which can meet the needs of real-time data acquisition and measurement.
Mass storage: Supports mass storage devices, which can store a large amount of measurement data to ensure data integrity and traceability.
Extensibility:
Scalability: The chassis has multiple slots and expansion interfaces that can expand more modules and devices to achieve more functions and applications.
Connection mode: Support a variety of connection modes, such as USB, Ethernet, etc., to facilitate users to connect and data transmission.
Application scenario:
Laboratory Measurement and testing: The SCXI-1102C can be used for a variety of measurement and testing applications in laboratory environments, including physics, engineering, biology, and more.
Automated test systems: In the industrial and manufacturing sectors, such cases can be used as part of automated test systems for high-throughput, repeatable testing and quality control.
Data acquisition and monitoring: The SCXI-1102C provides a modular platform that can be used to acquire and monitor data from a variety of sensors, including temperature, pressure, vibration, etc.

Product parameter

Model SCXI-1102C
Manufacturer National Instruments
Part Number 776572-02C
Type Voltage Input Module
Channels 32
Cutoff Frequency 10 kHz
Maximum Working Voltage ±10 V
Dimensions 1.2 by 6.8 by 8.0 in.
Weight 24.6 oz.

Application field

National Instruments SCXI-1102C Voltage Input Module

The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. This Voltage Input Module is designed for the signal conditioning of thermocouples, low-bandwidth volt and millivolt sources, 4 to 20 mA current sources, and 0 to 20 mA process-current sources. The NI SCXI-1102C can perform these measurements: current input, thermistors, voltage input, RTD, and thermocouple. It has a power requirement of 15 mA maximum at 5 V, and 150 mA maximum at ±15 V.

The gain/input range is a software-configurable setting that enables the user to select the correct amplification to completely utilize the range of the E/M Series DAQ instrument. For many applications, NI-DAQ selects the gain for the user based on the input range. If not, the user can choose the correct gain by utilizing the input signal voltage range and the full-scale limits of the SCXI-1102C output. The user can choose a gain of 1 or 100 per channel.

When the user is utilizing NI-DAQmx, they can configure software settings, such as sensor type and gain/input signal range in several ways. These include functions in the user’s application and task or global channel using the Measurement & Automation Explorer (MAX) tool. However, it is vital to realize that not all software-configurable settings are configurable both ways. If the user is utilizing the traditional NI-DAQ (Legacy), they can configure software settings (gain/input signal range, etc.) in three ways, including: functions in the user’s ADE, virtual channels properties in MAX, and module property pages in MAX. The device should be calibrated at least once a year. The NI device weighs 24.6 oz, and measures 1.2 x 6.8 x 8.0 in. in physical dimensions. It has a recommended operating temperature range of 0 to 50 °C, a storage temperature range of –20 to 70 °C, and a non-condensing humidity range of 10 to 90% RH.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363