Description
Technical Specifications
| Product Model | **MVI94-MCM-MHI** |
| Manufacturer | Prosoft Technology |
| Product Type | Modbus Master/Slave Communication Module |
| Compatibility | Allen-Bradley ControlLogix (1756 chassis) |
| Protocol Support | Modbus RTU/ASCII/TCP, MHI (Modbus Host Interface) |
| Communication Ports | 2x RS-232/485 (isolated) |
| Baud Rate | 300–115.2 kbps |
| Power Supply | 5 VDC via ControlLogix backplane (85 mA typical) |
| Operating Temperature | -40°C to +70°C |
| Certifications | UL, CE, RoHS, Class I Div 2 |
| Dimensions | 135 x 45 x 120 mm (fits single ControlLogix slot) |
Key Features and Advantages
The **MVI94-MCM-MHI** enables seamless integration of ControlLogix PLCs with Modbus networks. Its dual-channel design allows simultaneous Master/Slave operation, supporting up to 247 Modbus devices per port. Built-in message queuing optimizes PLC scan times, while galvanic isolation (2,500 Vrms) protects against ground loops. Prosoft’s **Configurator LX™** software simplifies mapping of Modbus registers to ControlLogix tags, with pre-tested AOIs (Add-On Instructions) for rapid deployment.
Dynamic address translation supports both 1-based and 0-based Modbus addressing. The module’s **MHI protocol** enables PLCs to act as Modbus TCP servers for SCADA integration. Ruggedized for harsh environments, it includes surge suppression (IEC 61000-4-5) and conformal coating for humidity resistance.
Application Areas
Industrial automation bridging between ControlLogix and legacy Modbus devices (e.g., meters, drives, HMIs). Water/wastewater treatment plant telemetry, oil & gas RTU communication, and building automation systems. Used for aggregating data from Modbus TCP-enabled IoT sensors into ControlLogix-based SCADA networks.
Related Products
- **MVI94-GSC**: Generic Serial Communication module
- **MVI69-MBS**: Modbus Slave module for CompactLogix
- **PS69-MCM-PK**: Modbus Master expansion for PowerFlex drives
- **ProSoft Connect Cloud™**: Remote Modbus-to-Cloud gateway
Installation and Configuration
**Installation**: Insert into ControlLogix chassis (slot 0-15). Terminate RS-485 networks with 120Ω resistors. Use shielded twisted-pair cables and ground shields at one end. Configure chassis slot addressing via RSLogix 5000/Studio 5000.
**Configuration**: Import AOI library into PLC project. Define Modbus data maps using Configurator LX. For TCP/IP, assign IP via BOOTP/DHCP or static configuration. Test connectivity with built-in diagnostic LEDs (Port Activity, Modbus Error).
Support and Diagnostics
ProSoft provides 24/7 technical support with a 3-year warranty. Onboard diagnostics include packet error counters, CRC failure logs, and slave response timeouts. Use **ProSoft Message Monitor** for real-time protocol analysis. Firmware updates via SD card slot (v3.1+).
Note: Verify Modbus register mapping compatibility with slave devices. For Hazardous Locations, follow ISA 12.12.01 guidelines during installation.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版
