Triconex 3626X | Safety Digital Input Module

Product Model:TRICONEX 3626X
Manufacturer:Schneider Electric
Product Type:Safety Digital Input Module
Input Channels:16 (SIL 3 compliant)
Input Voltage:24 VDC (18-30 VDC range)
Response Time:≤15 ms
Communication Protocol:TriBus (TMR architecture)
Operating Temperature:-40°C to +70°C
Certifications:IEC 61508, IEC 61511, ATEX
MTBF:≥150 years
Housing Material:Fire-retardant polycarbonate
Warranty:1 years

Category:

Description

“`html

Technical Specifications

Product Model **TRICONEX 3626X**
Manufacturer Schneider Electric
Product Type Safety Digital Input Module
Input Channels 16 (SIL 3 compliant)
Input Voltage 24 VDC (18-30 VDC range)
Response Time ≤15 ms
Communication Protocol TriBus (TMR architecture)
Operating Temperature -40°C to +70°C
Certifications IEC 61508, IEC 61511, ATEX
MTBF ≥150 years
Housing Material Fire-retardant polycarbonate
Warranty 5 years

Key Features & Advantages

The **TRICONEX 3626X** implements Triple Modular Redundancy (TMR) technology with three independent processors voting on safety-critical decisions, achieving 99.999% system availability. Its patented fault detection algorithms identify 98% of potential failures within 2 milliseconds, enabling automatic switchover to backup channels without process interruption. The module’s galvanic isolation (2.5kV AC between channels) prevents cross-circuit interference in hazardous environments.

Designed for mission-critical applications, the **TRICONEX 3626X** features live insertion capability for hot-swapping during continuous operations. The integrated HART 7 protocol support allows simultaneous digital communication with smart field devices while maintaining analog signal integrity. With IP66 front-panel sealing, it resists high-pressure washdowns and corrosive chemical exposure.

Applications

The **TRICONEX 3626X** is deployed in offshore platform Emergency Shutdown Systems (ESD) where it processes 200+ safety interlocks with deterministic response. In LNG liquefaction plants, it monitors cryogenic valve positions and gas detection sensors, maintaining functional safety during -50°C cold snaps. Nuclear power stations utilize its TMR architecture for reactor protection systems, achieving 10^-9 failure probability per hour.

Pharmaceutical batch processes leverage the module’s ATEX compliance for explosive atmosphere areas. Rail transportation systems integrate **TRICONEX 3626X** for signaling system fail-safe operations, processing 10,000+ daily safety votes with zero latency. Chemical tank farms employ its HART-enabled channels for smart valve positioners and corrosion monitoring transmitters.

Related Products

**TRICONEX 3704E**: SIL 3-certified analog input module for 4-20mA safety loops.

**TRICONEX 4351B**: Redundant communication module supporting Modbus TCP and OPC UA. **TRICONEX 3503E**: Main processor unit with 2/3/4 voting modes.

**TRICONEX 8312**: Intrinsically safe barrier for Zone 0 installations.

**TRICONEX 3627X**: 32-channel variant with enhanced diagnostics for large-scale ESD systems.

Installation & Maintenance

Installation preparation: Verify ground continuity (≤1Ω) before mounting **TRICONEX 3626X** in Zone 2 classified areas. Use shielded twisted-pair cables with 360° gland termination for noise immunity. Maintenance recommendations: Perform channel validation quarterly via TriStation 1131 software, checking <2% deviation across redundant processors. Replace terminal blocks every 5 years or after 10,000 insertion cycles.

Product Assurance

Every **TRICONEX 3626X** completes 500-hour accelerated life testing simulating 20 years of field operation. Our 5-year warranty includes 8-hour critical failure response and lifetime access to safety function templates. Certified by TÜV Rheinland for SIL 3 applications, the module is backed by Schneider Electric’s Global Safety Experts network providing 24/7 application engineering support.

“`

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com