Description
“`html
Technical Specifications
| Product Model | **TRICONEX 3626X** |
| Manufacturer | Schneider Electric |
| Product Type | Safety Digital Input Module |
| Input Channels | 16 (SIL 3 compliant) |
| Input Voltage | 24 VDC (18-30 VDC range) |
| Response Time | ≤15 ms |
| Communication Protocol | TriBus (TMR architecture) |
| Operating Temperature | -40°C to +70°C |
| Certifications | IEC 61508, IEC 61511, ATEX |
| MTBF | ≥150 years |
| Housing Material | Fire-retardant polycarbonate |
| Warranty | 5 years |
Key Features & Advantages
The **TRICONEX 3626X** implements Triple Modular Redundancy (TMR) technology with three independent processors voting on safety-critical decisions, achieving 99.999% system availability. Its patented fault detection algorithms identify 98% of potential failures within 2 milliseconds, enabling automatic switchover to backup channels without process interruption. The module’s galvanic isolation (2.5kV AC between channels) prevents cross-circuit interference in hazardous environments.
Designed for mission-critical applications, the **TRICONEX 3626X** features live insertion capability for hot-swapping during continuous operations. The integrated HART 7 protocol support allows simultaneous digital communication with smart field devices while maintaining analog signal integrity. With IP66 front-panel sealing, it resists high-pressure washdowns and corrosive chemical exposure.
Applications
The **TRICONEX 3626X** is deployed in offshore platform Emergency Shutdown Systems (ESD) where it processes 200+ safety interlocks with deterministic response. In LNG liquefaction plants, it monitors cryogenic valve positions and gas detection sensors, maintaining functional safety during -50°C cold snaps. Nuclear power stations utilize its TMR architecture for reactor protection systems, achieving 10^-9 failure probability per hour.
Pharmaceutical batch processes leverage the module’s ATEX compliance for explosive atmosphere areas. Rail transportation systems integrate **TRICONEX 3626X** for signaling system fail-safe operations, processing 10,000+ daily safety votes with zero latency. Chemical tank farms employ its HART-enabled channels for smart valve positioners and corrosion monitoring transmitters.
Related Products
**TRICONEX 3704E**: SIL 3-certified analog input module for 4-20mA safety loops.
**TRICONEX 8312**: Intrinsically safe barrier for Zone 0 installations.
**TRICONEX 3627X**: 32-channel variant with enhanced diagnostics for large-scale ESD systems.
Installation & Maintenance
Installation preparation: Verify ground continuity (≤1Ω) before mounting **TRICONEX 3626X** in Zone 2 classified areas. Use shielded twisted-pair cables with 360° gland termination for noise immunity. Maintenance recommendations: Perform channel validation quarterly via TriStation 1131 software, checking <2% deviation across redundant processors. Replace terminal blocks every 5 years or after 10,000 insertion cycles.
Product Assurance
Every **TRICONEX 3626X** completes 500-hour accelerated life testing simulating 20 years of field operation. Our 5-year warranty includes 8-hour critical failure response and lifetime access to safety function templates. Certified by TÜV Rheinland for SIL 3 applications, the module is backed by Schneider Electric’s Global Safety Experts network providing 24/7 application engineering support.
“`
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版