Description
Technical Specifications
| Product Model | AO3482 |
| Manufacturer | Triconex (Schneider Electric) |
| Product Type | Analog Output Safety Module |
| Output Channels | 8 isolated channels |
| Signal Range | 4-20mA / 0-10V DC (software selectable) |
| Resolution | 16-bit |
| Accuracy | ±0.05% of span |
| Isolation Voltage | 2500V RMS channel-to-system |
| Update Rate | 1ms per channel |
| Certifications | SIL 3, IEC 61508, ATEX Zone 2 |
| Operating Temperature | -40°C to +85°C |
| Warranty | 5 years |
Key Features and Advantages
The AO3482 delivers fault-tolerant analog control with triple redundant processing paths, achieving <0.01% annual drift for critical process loops. Its active current balancing technology maintains signal integrity even during power transients up to 300V surge events.
Safety-first design: Certified for SIL 3 applications with built-in HART 7 protocol support for smart actuator integration. The module’s galvanic isolation and reinforced barriers prevent ground loops in explosive atmospheres (ATEX Zone 2).
Advanced diagnostics: Features continuous wire-break detection and load monitoring with predictive maintenance alerts. Hot-swappable design enables module replacement without process interruption, while front-panel LEDs provide instant channel status visualization.

AO3482
Application Areas
In oil refineries, the AO3482 precisely controls emergency shutdown valves and turbine governors, maintaining SIL 3 compliance for API 670 machinery protection systems. Its fast update rate (<1ms) ensures responsive pressure control in FCCU units.
Power generation plants utilize this module for governor control of steam turbines and AVR systems in generators. The wide temperature range (-40°C to +85°C) supports outdoor installation in arctic LNG compressor stations.
Pharmaceutical manufacturing leverages its HART communication capability for smart control valves in cleanroom environments, ensuring FDA 21 CFR Part 11 compliance through audit-trail enabled configuration changes.
Related Products
AI3482: Analog input module with IEC 60751 RTD support
DI3482: 16-channel digital input module
TMR3482X: Triple modular redundant processor
PSD3480: 24V DC redundant power supply
FCM3482: Field communication gateway
Installation and Maintenance
Installation preparation: Use twisted-pair shielded cables (Belden 8761 or equivalent) for all AO3482 outputs. Maintain 50mm separation from AC power lines and ground shields at single point. Verify chassis ground resistance <1Ω before power-up.
Maintenance recommendations: Perform annual calibration verification using Triconex CAL-4000 test set. Replace terminal blocks every 5 years or 10,000 insertion cycles. Always discharge field capacitance before hot-swapping modules in explosive environments.
Product Assurance
The AO3482 undergoes 2,000-hour accelerated lifecycle testing and IEC 61000-4-4 EFT immunity validation. Schneider Electric provides SIL 3 certification packages and 24/7 critical support with guaranteed 6-hour response for safety system emergencies. The 5-year warranty covers all component failures except improper lightning surge protection incidents.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
中文版