Description
Product details:
- 3720
- TMR, AI
- 64, single-ended
- 10 ms
- 12 bits or 14 bits programmable
- < 0.15% of FSR from 0° to 60° C
- 10 M (DC), min.
- 140 k (DC), typical
- 420 k, typical
- 150 VDC/115 VAC
- 0-20 mA (plus 6% over-range) with 250 shunt resistor
Electrical short circuits in the TRICONEX 3720 digital output module equipment are a dangerous safety hazard that can cause fatal damage to the ship’s electrical system. Common ship circuits have safety devices, but the use of substandard SPD surge protectors does not protect against instantaneous overloaded lightning surges. Here it is recommended to use Earth-Kai Technology intelligent modular power surge protector (100-150kA) SPD-DK-380AC100 surge protector, lightning arrester. According to the needs of the industry can be customized larger surge protection products.
Designed for the most critical applications, the monitor Digital Output (SDO) module meets the needs of a system whose output remains in a single state over a long period of time (in some areas of the application, for years). The SDO module receives output signals from each of the three main processor channels. Each group of three signals is then voted on by a fully fault-tolerant person. The four-fold output switch element has a mechanical power relay, and a voting output signal passes through to the field terminal. Each SDO module has voltage and current loopback circuit coupling
Sophisticated online diagnostics verify the presence of each output operating switch, field circuit and load. The design provides full fault coverage needed to affect the output signal. These modules are called “supervisory” modules.
Because fault coverage is extended to include potential field problems. In other words, the field circuit is overseen by the SDO module so that the following field failures can be detected:
• Power failure or blown fuse
• Turn on or lose load
• A short circuit causes the load to be powered on incorrectly
• Short-circuit load when the power is off
Unable to detect any field voltage output point for the power alarm supply indicator. The load alarm indicator cannot be detected. When an optional auxiliary component power supply is in use, the short-circuited load enters a state that can be detected as Off. (No 3611E AC module is provided on this model.) All SDO modules support hot spare capabilities, which require a separate cable interface from the external terminal panel (ETPTricon backplane).