8290-191 | Digital Speed Control Module (Governor)

Product Model **8290-191**
Manufacturer Woodward
Product Type Digital Speed Control Module (Governor)
Input Voltage 18-32 VDC (24 VDC nominal)
Control Output ±20 mA, 4-20 mA analog, PWM
Speed Range 0-12,000 RPM (configurable)
Accuracy ±0.25% of setpoint
Communication Modbus RTU/TCP, CANbus J1939
Operating Temperature -40°C to +85°C
Protection Class IP67 (NEMA 4X)
Certifications UL 508, CE, ATEX Zone 2
Dimensions 150 x 90 x 45 mm
Category:

Description

Technical Specifications

Product Model **8290-191**
Manufacturer Woodward
Product Type Digital Speed Control Module (Governor)
Input Voltage 18-32 VDC (24 VDC nominal)
Control Output ±20 mA, 4-20 mA analog, PWM
Speed Range 0-12,000 RPM (configurable)
Accuracy ±0.25% of setpoint
Communication Modbus RTU/TCP, CANbus J1939
Operating Temperature -40°C to +85°C
Protection Class IP67 (NEMA 4X)
Certifications UL 508, CE, ATEX Zone 2
Dimensions 150 x 90 x 45 mm

Key Features and Advantages

The **8290-191** provides precision speed regulation for gas/diesel engines and turbines. Its adaptive PID control algorithm dynamically adjusts to load changes, maintaining ±0.1% stability under transient conditions. Dual redundant processors with failover logic ensure continuous operation, while integrated surge protection (IEC 61000-4-5) safeguards against voltage spikes. The module supports isochronous/droop modes and load-sharing via CANbus for multi-engine synchronization.

Woodward’s **Toolkit™** software enables graphical configuration of response curves and fault diagnostics. The cast aluminum housing with conductive coating resists EMI/RFI interference, critical in power generation environments. Built-in data logging stores 1,000+ runtime events for failure analysis. Optional SAE J1939 compliance simplifies integration with mobile equipment.

8290-191

Application Areas

Prime power generation for backup generators, marine propulsion engine control, and gas compressor stations. Used in CHP (Combined Heat & Power) systems for frequency regulation and in oilfield drilling rigs for hydraulic pump speed management. Also deployed in renewable energy hybrids to balance diesel/battery loads.

Related Products

Installation and Maintenance

**Installation**: Mount vertically using M6 bolts to minimize vibration transfer. Shield all signal cables and maintain 50 cm separation from high-current lines. Use Woodward-approved **Cable Kit 8270-100** for CANbus connections. Ground the chassis directly to the engine block (≤0.1 Ω resistance).

**Maintenance**: Perform annual calibration with NIST-traceable RPM source. Replace the lithium backup battery (CR2450) every 5 years to retain configuration data. Clean air vents quarterly using low-pressure compressed air. Update firmware via isolated USB interface only.

Product Assurance

Woodward’s **8290-191** undergoes 1,000-hour accelerated life testing with thermal cycling (-40°C to +125°C). The 5-year warranty covers all electronic components, with 24/7 global technical support. Compliance with ISO 8528-5 for genset transient response ensures grid-code compatibility. Full documentation includes SIL 2 safety case reports for critical installations.