Product ID:3BHE026284R0102
ABB Type Designation:UAD215A102
Catalog Description:UA D215 A102: PEC80 Converter Signal Int
Long Description:UA D215 A102: PEC80 Converter Signal Int
Country of Origin:Switzerland (CH)
Customs Tariff Number:85371092
Product Net Depth / Length:440 mm
Product Net Height:43 mm
Product Net Weight:0.4 kg
3BHE026284R0102 UA D215 A102 15V, 1000V CSI Converter Signal Interface for D5 UN6800 & UNL 13300
The excitation system consists of two parts: excitation control and excitation power output. It can not only provide branch current for the generator plant, but also complete the establishment of the generator branch magnetic field. By effectively controlling the excitation, it is helpful to ensure the normal operation of the generator. When the generator fails, the excitation current can be effectively adjusted to ensure the safe operation of the generator. The role of the generator excitation system is mainly manifested in the following four aspects. First, the voltage control function. In order to ensure the normal operation of the generator, it is necessary to do a good job in voltage control. It should be ensured that the system provides excitation power for the generator under normal operating conditions, and in combination with different load conditions, the magnitude of the excitation current can be effectively adjusted to achieve effective maintenance of a given voltage level. Second, reactive power distribution. It is necessary to reasonably allocate the reactive power of the generator set in the excitation system and give full play to the role of the regulation system to achieve effective control of the power factor, current and reactive power parameters of the generator set. Third, ensure the safe operation of power equipment. During the operation of power equipment, it is necessary to improve the dynamic stability and venous stability of the system. Once a short-circuit fault occurs in the power generation system, it is necessary to cut off the fault in time to effectively maintain the voltage in the power system, so as to accelerate the rapid recovery of the voltage and ensure the safety of power equipment operation.
Recommended model:
PPC380AE102 HIEE300885R0102
PPC380AE02 HIEE300885R0102
PPA322B HIEE300016R2 HIEE400235R1
PMA323BE HIEE300308R1
NU8976A99 HIER466665R0099 HIEE320693R0001
LT8978BV1 HIEE320639R0001
KX8974CV24 HIEE320606R1
KUC321AE HIEE300698R0001
HIEE451220R1 HI903897-310/49 RTA108BE
HIEE451116R0001 FM9925A-E