IS220PRTDH1A Processor board operation
IS220PRTDH1A I/O packets or modules function specific acquisition boards connected to processor boards. When an input power supply is applied, the soft-start circuit gradually increases the available voltage on the processor board. The processor is reset and turned off, and the local power is turned on in sequence. After completing the self-check routine, the processor loads the application code from the flash memory specific to the I/O package or module type. In order to verify whether the application code, acquisition board and terminal board match correctly, the application code reads the board ID information. When the match is good, the processor attempts to initiate an Ethernet connection by requesting a network address.
The industry-standard Dynamic Host Configuration Protocol (DHCP) and the unique identifier of the terminal board are used in the address request. Once the Ethernet is started, the CPU runs applications that program the onboard logic and allow the acquisition board to start working.
The entire circuit needed to enable I/O packets to run from one or two Ethernet inputs is included in the processor application code. When two Ethernet inputs are used, both network paths are always active. I/O packets or module operations will not be affected by any single network failure, and working network connections will show failure. This configuration is more fault tolerant than a traditional hot backup system, in which the second port is used only when the primary port fails. The processor’s Ethernet port automatically negotiates between half-duplex and full-duplex operations at speeds between 10 MB/s and 100 MB/s.
The processor board is common to all Mark VIe Ethernet I/O packages or modules. It contains the following:
A fast processor with RAM and flash memory comes first.
Two fully independent 10/100 Ethernet port plugs
Hardware reset and watchdog timer circuit
Internal temperature sensor
An LED indicating the status
The ability to read ids and electronic identifiers on other boards
Input power connector with current limiter and slow start function
Local power, which also includes monitoring and sorting
Provide 15 years of industrial automation and electrical materials complete solutions
Customers in the field of electrical trade, a wide range of product choices, fast
Delivery and further services. Always provide the best solutions in automation and industry
Spare parts exceed customer expectations to achieve superior business performance
Provide efficient solution for automation spare parts, apply new technology and develop
Excellent new products bring real benefits to customers and add value to stakeholders.
Quick Contact
Purchase advisory hotline :18059884797 (wechat same number)
QQ: 3095989363
Email: sales@xiongbagk,cn
Address: 217-01, Building 3, Core Yungu, Recruitment Bureau, No. 429, Nanbin Avenue, Zhangzhou Development Zone, Fujian Province
Company: Zhangzhou Branch of Xiamen Xiongba E-commerce Co., LTD
➪ condition: brand new original packaging
➪ payment: inventory items 100% T/T before shipment
➪ availability: 24/7 service and free online offer
➪ warranty: all new or repaired parts have the warranty period of 12 months
GE | Bently Nevada | Triconex DCS | ABB Bailey |
GE DS3800NASB1B1C | BENTLY 3500/50-01-00-02 | TRICONEX 9765-210 | CI801-eA(3BSE022366R2) |
GE DS3800NAIE1A1A | BENTLY 3500/50-01-00-02 | TRICONEX 9761-210 | CI801 3BSE022366R1 |
GE DS3800NAIB | BENTLY 3500/50-01-00-01 | TRICONEX 9668-110 | CI627A 3BSC980006R213 |
GE DS3800NADC1D1D | BENTLY 3500/50-01-00-00 | TRICONEX 9662-610 | CI546 3BSE012545R1 |
GE DS3800NADC1C1A | BENTLY 3500/50-01-00 | TRICONEX 9651-110 | CI522A(3BSE018283R1) |
GE DS3800NADB1D1D | BENTLY 3500/50 3500/50M | TRICONEX 9563-810 | CI522A 3BSE012545R1 |
GE DS3800NADB1B1B | BENTLY 3500/50 133388-02 | TRICONEX 9561-810 | CB801/3BSE042245R1 |
GE DS3800NADA1F1G | BENTLY 3500/50 | TRICONEX 4329G | CB801 3BSE042245R1 |
GE DS3800NADA1F1F | BENTLY 3500/46M | TRICONEX 4351B | C87-11006 (FAU810 FAU800 ) |
GE DS3800NADA1E1F | BENTLY 3500/45 P/N140072-04 | TRICONEX 4119A | BRC300 PHCBRC300P-HC-BRC-300 |
GE DS3800NADA1E1E | BENTLY 3500/45 176449-04 | 7400206-100 | BRC-100 BRC-300 |
GE DS3800NADA | BENTLY 3500/45140072-04 | 7400209-010 | BRC100 BRC-100 P-HC-BRC-10000000 |
GE DS3800N0CB1J1G | BENTLY 3500/45-01-00 | 7400213-100 | BC810K01 3BSE031154R1 |
GE DS3800N0AA1F1D | BENTLY 3500/45-01 | TRICONEX 4508I/O | BB510 3BSE001693R2 |
GE DS3800HXTAIEIE | BENTLY 3500/45 176449-04 | TRICONEX 8307A | BB150/3BSE003616R1 |
GE DS3800HXTA | BENTLY 3500/45 140072-04 | TRICONEX 8305A | BB150 / 3BSE003616R1 |
GE DS3800HXRC1E1CGE DS3800HXRC1F1C | BENTLY 3500/45 | TRICONEX 8302A | BB150 |
GE DS3800HXRC1E1C | BENTLY 3500/44M | TRICONEX MP2101 | B4LE 1KHL015045P0001 |
GE DS3800HXRC1D1C | BENTLY 3500/42 MNSFP350042M | TRICONEX MP6004 | ARC093AE01 HIEE300661R0001 |
GE DS3800HXRC | BENTLY 3500/42M-01-00 | TRICONEX PM6301A | APBU-44C |
GE DS3800HXRB1D1D | BENTLY 3500/42M 176449-02 | TRICONEX 8306AI/O | AO810 3BSE008522R1 |
GE DS3800HXRB1B1B | BENTLY 3500/42M 138708-01 | MP 3008 ITCC | AMC-DC/3ADT309900R1 |
GE DS3800HXRA1F1F | BENTLY 3500/42M 128229-01 | 4000093-310 | AI930S、TU551-CS31 C0 |
GE DS3800HXRA1E1E | BENTLY 3500/42M | 4000056-002 | AI930S |
GE DS3800HXRA | BENTLY 3500/42140471-01 | 4000094-310 | AI895 3BSC690086R1 |
GE DS3800HXPEPR | BENTLY 3500/42-09-00 | 4000103-510 | AI845(3BSE023675R1) |
GE DS3800HXPE1A1A | BENTLY 3500/42-04-00 | TRICONEX 3704E | AI845 AI810 |
GE DS3800HXPD1C1E | BENTLY 3500/42-01-00 | TRICONEX 3805E | AI830A 3BSE040662R1 |
GE DS3800HXPD1C1D | BENTLY 3500/42 140471-01 | TRICONEX 3805H | AI830 3BSE008518R1 |
GE DS3800HXPD1B1D | BENTLY 3500/42 | 3700A 3721 | AI815(3BSE052604R1) |
GE DS3800HXPC1D1F | BENTLY 3500/40M | 3700A 3700 | AI810 3BSE008516R1 |
GE DS3800HXPA1F1H | BENTLY 3500/40-01-00 | TRICONEX 3636R | AI801 |
GE DS3800HXPA1D1D | BENTLY 3500/33 149986-01 | TRICONEX 3700A | AI086-8/4 |
GE DS3800HXPA1B1A | BENTLY 3500/33-01-00 | 3625C1 3625 | AGPS-21C |
GE DS3800HXMA1L1K | BENTLY 3500/33 | 3624 3625 | ACM800PM864AK01/PM861AK02 |
GE DS3800HXCA1D1D | BENTLY 3500/32 125712-01 | 3503E 3721 | AC800M PM866AK01/3BSE076939R1 |
GE DS3800HXCA1A1A | BENTLY 3500/32-01-00 | TRICONEX 3604E | AC800F PM802F /3BDH000002R1 PM592-ETH |
GE DS3800HVDB1K1G | BENTLY 3500/32 125712-01 | TRICONEX 3607E | 89NU01C-E GJR2329100R0100 |
GE DS3800HVDB1J1F | BENTLY 3500/32 | TRICONEX 3623T | 88UM01A GJR2329800R0100 |
GE DS3800HUMB1B1B | BENTLY 3500/25-A01-B01-C00 | TRICONEX 3601E | 88FV01E/GJR2332300R0200 |
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com