Description
Product details:
German EPRO module MMS3120/022-000 Spot sales:
The configuration of the MMS3120/022-000 monitor is done with a portable or desktop PC,
the MMS3120/022-000 is connected to the socket on the front MMS3120/022-000 side of the
monitor via an RS232 interface circuit. The software and measurement results and status monitoring
required for the MMS3120/022-000 configuration and the MMS3120/022-000 connection cable
between the computer and the monitor are part of the MMS6910 Configuration kit. In addition, the
tool MMS3120/022-000 package comes with a system manual containing the required instructions
for testing and monitoring MMS3120/022-000 measurements and status monitoring.
MMS3120/022-000German EPRO module MMS3120/022-000 Spot sales:
MMS3120/022-000 dual channel bearing vibration monitor is a module of MMS6000
mechanical monitoring system. The board is MMS3120/022-000 microprocessor control module is
designed for measuring and monitoring all kinds of steam turbine, MMS3120/022-000 compressor,
fan and gear box and other machinery bearing vibration. The MMS3120/022-000 can also use
piezoelectric sensors instead of seismic sensors. Importantly, the corresponding amplifying
MMS3120/022-000 synthesizes a sensor signal proportional to the vibration frequency. Thus, the
signal will be converted to a signal proportional to the vibration frequency of MMS3120/022-000. The
two channels of the MMS3120/022-000 monitor are independent of each other. Each channel of the MMS3120/022-000
can be configured separately (such as measuring range, sensor type and limit value, etc.). Each channel
calculates its own eigenvalue and MMS3120/022-000 and monitors its overrun and system sensor failures.
German EPRO module MMS3120/022-000 Spot sales:
MMS3120/022-000 In the dual channel independent measurement mode, MMS3120/022-000 each
channel can be separately set two groups of alarm value and danger value. The mode used for the
dual channel joint MMS3120/022-000 is described later. In order to avoid the change of MMS3120/022-000
measurement value near the limit repeatedly trigger the alarm, MMS3120/022-000 can set the alarm lag value, MMS3120/022-000 in the
full range of 1-20% choice. b. Limit multiplier and MMS3120/022-000
multiplier X In special circumstances such as over critical speed, in order to avoid unnecessary MMS3120/022-000
alarm or jump, you can activate the function of MMS3120/022-000 limit multiplier in the software, and set the
multiplier X (1.00~5.00). When using MMS3120/022-000, d18 should be low. The multiplication factor X affects both the alarm value and the danger value. c. Alarm output
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com