Description
8C-PDILA1 HONEYWELL Series 8 Controller
This text mainly describes the size of the Series 8 I/O and the functionality of the I/O module. Here is a summary of the text:
Series 8 I/O has a smaller connection footprint than traditional rack-based systems and provides useful, maintainable
process equipment. This helps reduce the total installation cost.
The size of IOTA varies from application to application. In general, the simulation module has 16 points, with a 6-inch (152 mm)
IOTA for non-redundant applications and a 12-inch (304mm) IOTA for redundant applications. The separate modules have 32
points, with a 9-inch (228mm) IOTA for non-redundant applications and a 12-inch (304mm) IOTA for redundant applications.
Information on specific module sizes can be found in the model table.
The functions of several different types of analog input and output modules are described. Includes TC/RTD modules that support thermocouple
(TC) and resistance temperature device (RTD) inputs, modules that support analog inputs (both single-ended and HART versions), modules
that support differential analog inputs, and modules that support analog outputs (including standard 4-20mA DC outputs and HART outputs).
Overall, this text provides information on the size and functionality of Series 8 I/O, as well as advantages over traditional rack-based systems.
This text mainly describes the functions of the digital input and output modules and the field connection of the Series 8. Here is a summary of the text:
The digital Input Sequence event module accepts 24VDC discrete signals as discrete inputs, can be time-stamped,
and supports 1ms resolution event sequences.
Digital input 24VDC module senses 24V signal as discrete input.
The digital input pulse accumulation module accepts 24VDC discrete signal as discrete input, can be configured with
16 pulse accumulation, and supports pulse accumulation and frequency measurement by channel. Route 17 to 32 can be configured as DI.
Digital output 24VDC module is a current sinking digital output, the output is protected by electronic short circuit.
DO relay expansion boards with digital outputs with NO or NC dry contacts can be used for low power or high power applications.
Series 8 field connections use standard modular connectors whose modularity allows for disassembly and insertion of
field wiring, greatly reducing installation and maintenance procedures.
Series 8 field connectors accept multi-strand stranding up to 12 AWG / 2.5 mm2.
The dimensions of IOTA are nominal (6 inches = 152 mm, 9 inches =228 mm, 12 inches =304 mm). I/O modules and their
respective associated IOtas are shown in the table below, and I/O modules are supported by one or more IOtas.
Please contact Sunny sales@xiongbagk.cn for the best price.