A413240 METSO CIRCUIT BOARD MODULE ASSEMBLY

The redundant power supply is a power supply used in the server, which is composed of two identical power

supplies. The chip controls the power supply for load balancing. When one power supply fails, the

other power supply can take over its work immediately.

Category:

Description

A413240 CIRCUIT BOARD MODULE ASSEMBLY

The redundant power supply is a power supply used in the server, which is composed of two identical power

supplies. The chip controls the power supply for load balancing. When one power supply fails, the

other power supply can take over its work immediately. Redundant power supply is used to achieve

high availability of server system. In addition to servers, disk array systems are also widely used.

effect

RPS Power supply Redundant Power System (RPS) Used as external DC power supply for some switches

RPS can be used as a redundant backup power source for switches or routers:

If the RPS and the receiving device use the same AC power supply system, the RPS can continue to supply

DC power to the faulty device to ensure the normal running of the device when the internal power supply of the receiving device is abnormal.

If the RPS and the receiving device use different AC power supply systems, DC power supply can be

provided when the external AC power supply of the receiving device fails, ensuring the normal running of the device.

A413240

disposition

Redundant power supply for servers can be configured in many ways, such as:

1+1 Power supply configuration: indicates that the server can work properly with one power supply module. However, it is

configured with two power supply modules, one of which is backed up as a redundant power supply.

2+1 Power supply configuration: indicates that the server can work properly if it has two power modules, but three power

modules are configured. One power module is backed up as a redundant power supply.

2+2 power supply configuration: indicates that the server can work properly with two power supply modules (Psus).

However, in configuration, the server has four Psus, two of which are backed up as redundant Psus.

As for what kind of power configuration a server should use, one depends on how many power modules the server can

connect to, and the other depends on the use and importance of the server. For important servers that are

not suitable for downtime, sufficient redundant power supply should be provided if funds allow.

For a server with redundant power supply modules, when one of the power supply modules fails, the redundant power supply

immediately goes into operation, and the mainboard buzzer sounds an alarm.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com