MCD5-0195B-T5-G2X-00-CV2  VLT Soft Starter MCD 500

Soft start: Current limit, Current ramp, Kickstart, AAC Adaptive Acceleration Control
• Soft stop: Timed voltage ramp, AAC Adaptive Control, DC brake
• Motor protection: Motor connection, Power loss, Phase loss, Mains frequency, Current imbalance, Motor thermistor, Motor overload
• System protection: Phase sequence, Excess start time, Undercurrent, Instantaneous overcurrent, Bypass relay overload, Heatsink temperature
• Metering: Current, Motor temperature, Motor kW, motor kVA, Motor pf
• Control option: Local control panel plus remote inputs/outputs. Dedicated output for MCD LCP 501
• Network communication: options for DeviceNet, Modbus, PROFIBUS and USB
• Bypass:7.5 ~ 500 kW internally bypassed; 630 ~ 800 kW dedicated terminals for external bypass connection

Category:

Description

MCD5-0195B-T5-G2X-00-CV2  VLT Soft Starter MCD 500

Soft start: Current limit, Current ramp, Kickstart, AAC Adaptive Acceleration Control
• Soft stop: Timed voltage ramp, AAC Adaptive Control, DC brake
• Motor protection: Motor connection, Power loss, Phase loss, Mains frequency, Current imbalance, Motor thermistor, Motor overload
• System protection: Phase sequence, Excess start time, Undercurrent, Instantaneous overcurrent, Bypass relay overload, Heatsink temperature
• Metering: Current, Motor temperature, Motor kW, motor kVA, Motor pf
• Control option: Local control panel plus remote inputs/outputs. Dedicated output for MCD LCP 501
• Network communication: options for DeviceNet, Modbus, PROFIBUS and USB
• Bypass:7.5 ~ 500 kW internally bypassed; 630 ~ 800 kW dedicated terminals for external bypass connection

MCD 201
• Soft start/stop: Timed voltage ramp
• Motor protection: not included
• System protection:not included
• Metering: not included
• Start/stop control: via inputs or via optional controller
• Network communication: optional
• Bypass: Internally bypassed
MCD 202
• Soft start: Current limit
• Soft stop: Timed voltage ramp
• Motor protection: Thermistor, Motor overload, Phase imbalance
• System protection: Phase rotation, Excess start time, Bypass overload & Instantaneous overload
• Metering: optional extra
• Start/stop control: via inputs or via optional controller
• Network communication: optional
• Bypass: Internally bypassed
MCD 201 and MCD 202
• Current: 7.5 kW ~ 110 kW @400 V
• Mains voltage: 200 ~ 575 VAC
• Supply frequency: 45 ~ 66 Hz
• Enclosure: 7.5 ~ 55 kW IP 20, 75 ~ 110 kW IP00

MCD5-0195B-T5-G2X-00-CV2

AAC is the next evolution in soft starter technology. Using AAC, the soft starter learns your motor’s performance during
start and stop, then adjusts control to optimize performance. The soft starter estimates the motor’s speed throughout each
AAC start and stop, and adjusts power to the motor to provide the selected acceleration or deceleration profile.
AAC is largely unaffected by changes in load, and is particularly suitable for pumping situations.
AAC offers three starting and stopping profiles: early, constant and late acceleration/deceleration.

AC53 utilisation codes describe the current rating for soft starters under specified operating conditions.
The utilisation code determines the maximum motor size the soft starter can be used with, under the specified conditions. The
current rating may change under different operating conditions.
AC53a: Non-bypassed soft starters
The rating depends on the number of starts per hour, the length and current level of the start, and the percentage of the operating
cycle that the soft starter will be running (passing current).

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “MCD5-0195B-T5-G2X-00-CV2  VLT Soft Starter MCD 500”

Your email address will not be published. Required fields are marked *

Post comment