AZM160-22YP-B1S Operating instructions Solenoid interlock

• Thermoplastic enclosure
• Manual / Emergency release
• Long life
Double insulated X
• High holding force 2,000 N
• Adjustable ball latch up to 150 N
• 30 N latching force
• Wiring compartment

Category:

Description

AZM160-22YP-B1S Operating instructions Solenoid interlock

• Thermoplastic enclosure
• Manual / Emergency release
• Long life
Double insulated X
• High holding force 2,000 N
• Adjustable ball latch up to 150 N
• 30 N latching force
• Wiring compartment
• Actuation on de-energisation or energisation
• 4 cable entries
• Mounting holes in base
• 24 VAC/DC
• 110 VAC
• 230 VAC
Always state required supply voltage when ordering

To safeguard up to Control Category 3 to EN 954-1, the Safety System Package No. 13 can be used.
This comprises an AES 1235 guard door monitor, an AZS 2305 fail-safe delay timer, an AZM 160-23ypk,
an AZM 160-B1S actuator, a Pg cable gland and safety screws with unidirectional screwdriver slot.

AZM160-22YP-B1S

Further variants not shown here are available on enquiry.
The applicable ordering suffix is added at the end of the part number of the solenoid interlock.
• Available with 5 N latching force, ordering suffix -2254
• With M 16 x 1.5 cable entry, ordering suffix -M16
• With gold-plated contacts (0.3 µm), ordering suffix -1637

This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete
version in the vicinity of the device. 1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and putting the component into operation.
The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “AZM160-22YP-B1S Operating instructions Solenoid interlock”

Your email address will not be published. Required fields are marked *

Post comment