YS1700-000/A34 Programmable Indicating Controller

The monitoring and operation display is provided in color, and input and output values, various constants, and incorporated
control functions can be set freely using key switches on the front panel. The monitoring displays include LOOP Display,
TREND Display, ALARM Display, and METER Display which provides information in much the same way as analog meters.

Category:

Description

YS1700-000/A34 Programmable Indicating Controller

Features
• Color LCD display
The monitoring and operation display is provided in color, and input and output values, various constants, and incorporated
control functions can be set freely using key switches on the front panel. The monitoring displays include LOOP Display,
TREND Display, ALARM Display, and METER Display which provides information in much the same way as analog meters.
• Failsafe function
Two CPUs are configured to provide manual operations and displays even if one of the CPUs becomes faulty.

Moreover, because the instrument incorporates a hard manual circuit independent of the digital circuit, it can continue

to generate manipulated output variables even if the digital circuit that includes the CPUs fails.
• AC/DC-common power supply with wide operating voltage range.
The instrument can be powered by either AC (100 V AC) or DC (24 V DC).
• The front panel is dust- and water-proof (conforming to IP54).
• Abundant communication functions

YS1700-000/A34Definition of Terms
• PV: Process variable input from process
• SV: Setpoint regarded as a control target
• MV: Manipulated variable for operating control elements such as valves.
• PID control: Control system based on action which combined three elements: proportional (P) action, integral (I) action, and
derivative (D) action.
• M mode: Mode in which manipulated output variables are operated manually.
• A mode: Mode in which MV is automatically controlled based on YS1000’s setpoint
• C mode: Mode in which MV is controlled based on an external setpoint
• Multi-function mode: Modes of the three preinstalled functions (single-loop mode, cascade mode, and selector mode)
• Programmable mode: Mode in which input/output or control computation is programmed
• User program: A program created using the YSS1000 Setting Software (available as an option)

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “YS1700-000/A34 Programmable Indicating Controller”

Your email address will not be published. Required fields are marked *

Post comment