GE WES5302-150 Network interface slave station module

Embedded system CPU The traditional embedded domain refers to a very broad category, is the main application domain of processors in addition to the server and PC domain. "Embedded" means that in many chips, the processors they contain are as hidden as they are embedded inside. In recent years, with the further development of various

REF542plus 1VCR007346 G0012

REF542plus SACE750090R0002 Feeder terminal

Compact digital bay control technology solution Not active product since 2020 The REF 542plus feeder terminal is a compact digital bay control technology solution. It can be used in several different medium voltage applications, such as in feeder protection, transformer protection and motor protection. The feeder terminal REF 542plus, like its predecessor REF 542, combines

ICS TRIPLEX T8846 PP49283-8 Terminal board

CPU structure Generally speaking, the structure of CPU can be roughly divided into operation logic components, register components and control components. The so-called operation logic unit, mainly able to carry out related logic operations, such as: can perform shift operation and logic operation, in addition to can also perform fixed point or floating-point arithmetic operation

100031593.10 LSU-112DG

DEIF LSU-112DG 100031593.10 distributor

①, current protection: (according to the setting principle of protection, protection range and principle characteristics) A, overcurrent protection - is to avoid the maximum load current that may appear in the protected equipment or line to set. Non-fault current, such as large motor starting current (short time) and traversing short circuit current, to ensure the

ICS TRIPLEX T8850 5600389 Terminal board

The relay protection device should meet the requirements of reliability, selectivity, sensitivity and quickness: the four "sex" is closely related, both contradictory and unified. selectivity -- Indicates that the fault is first removed by the protection of the faulty device or circuit breaker. When the protection of the faulty device or circuit breaker refuses to

CE3008 KJ2005X1-MQ1/12P6381X022

CE3008 Communication module

In comparison, the use of wireless DATA transmission module to establish a dedicated wireless data transmission mode than other ways have the following advantages, the following introduces the use of data-6106 wireless data transmission module to establish a dedicated wireless data transmission mode compared to the advantages of wired communication. Cheap cost Cable communication mode

5SHX2645L0004 3BHB003154R0101

3BHB003154R0101 3BHL000389P0104 IGCT module

Classification of IGCT In terms of internal structure, IGCT can be divided into the following three categories: (1) Asymmetric It is a pure PNPN thyristor structure. The device can withstand high voltage in the forward direction, but it does not have the ability to withstand reverse voltage and cannot flow through reverse current. It is

DEIF SCM-1 Measurement module

The SCM-1 module consists of three boards connected by an eight wired bus on the front side (not the backplane bus). The boards for SCM-1 are named SCM-A, SCM-B and SCM-C and these names can be found on the boards. SCM-A board: Two relay-boards OPR-1 can be mounted. One for output for a mechanical speed