Unitrol 1010 powerful small indirect excitation system

UNITROL 1010 is a powerful small indirect excitation system with built-in support for dual

channels for advanced load distribution, rotating diode monitoring, automatic synchronization and

multiple all-in-one communication options in parallel running units.

The UNITROL 1010 is a voltage regulator in the UNITROL 1000 series designed for use in

small and medium-sized synchronous generators and industrial machines.

Category:

Description

Unitrol 1010 powerful small indirect excitation system

UNITROL 1010 is a powerful small indirect excitation system with built-in support for dual

channels for advanced load distribution, rotating diode monitoring, automatic synchronization and

multiple all-in-one communication options in parallel running units.

The UNITROL 1010 is a voltage regulator in the UNITROL 1000 series designed for use in

small and medium-sized synchronous generators and industrial machines. IGBT semiconductor

devices based on advanced microprocessor technology and allowing current outputs up to 10ADC for continuous operation.

The UNITROL 1010 performs high performance in harsh conditions and different temperature ranges and

is fully compliant with DNV and UL standards. The additional features of UNITROL 1010 compared to the

previous version are Ethernet,USB connectivity, data and event logging and many new features.

The UNITROL 1010 is a miniaturized device designed for devices with excitation currents up to 10A.

Share the same interface and size as the UNITROL 1020.

Obey these safety precautions before you do work on the system:
1. Clearly identify the work location and equipment.
2. Disconnect all possible voltage sources. Make sure that reconnection is not
possible. Lock out and tag out.
• Open the main disconnecting device of the AVR.
• Disconnect any external power sources from the control circuits before
you do work on the control cables.
• If you have a permanent magnet generator connected to the AVR,
disconnect it from the AVR with a safety switch or by other means.
• After you disconnect the AVR, always wait for 5 minutes to let the
intermediate circuit capacitors discharge before you continue.
• Do not do work on the AVR when the amber warning LED flashes.
3. Protect any other energized parts in the work location against contact.
4. Take special precautions when you are near bare conductors.
5. Measure that the installation is de-energized.
• Use a multimeter with an impedance of at least 1 Mohm.
• Make sure that the voltage between the AVR input power terminals
(PWR L1, PWR L2 and PWR L3) and the grounding terminal (PE) is near
0 V.
• Make sure that the voltage between the AVR output terminals (IE+, IEand ExCap) and the grounding terminal (PE) is close to 0 V.
6. Install temporary grounding as required by the local regulations.
7. Ask for a permit to work from the person in control of the electrical
installation work.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “Unitrol 1010 powerful small indirect excitation system”

Your email address will not be published. Required fields are marked *

Post comment