1746-NO4V Allen-Bradley SLC 500 analog output module

The Allen-Bradley 1746-NO4V is a four (4) point, non-isolated SLC 500 standard analog voltage output module. It has an output range of -10 to 10 volts -1 LSB DC, with the backplane rated for 55 mah at 5 volts and 145 mah at 24 volts. By activating the external SW1, the external 24 VDC power supply can be used for the module. If the backplane power supply is sufficient, the backplane power supply can be used as the power supply for the module instead of the external power supply. The 1746-NO4V features 500 volt DC field wiring to backplane isolation with a maximum load reactance of 1 F and a maximum load current of 10 mA.

The module is a factory calibration module that uses a 16-bit binary complement binary communication format. The 1746-NO4V is packaged in an open housing and mounted on the 1746 chassis. It also comes with an LED status indicator and a removable terminal board (RTB). The recommended wire size for this module is #14 AWG maximum wire size. The update time of all parallel channels was 512 s, and the step response time was 2.5 ms at 95% time. The 1746-NO4V has an operating temperature range of 32 to 140 degrees Fahrenheit and a non-operating temperature range of -40 to 185 degrees Fahrenheit, with a non-condensing relative humidity of 5 to 95% for operation and storage. The 1746-NO4V has a maximum overall accuracy drift of +/-54 ppm/ C at full scale.

The Allen-Bradley 1746-NO4V module is a Programmable Logic controller (PLC) analog output module belonging to the SLC 500 product platform. The module’s output channel generates a voltage signal in the range of -10 to +10VDC.

When installing this module into the case, you can use certain guidelines to determine the ideal slot or case assignment for the module. Consider two (2) general factors such as ambient temperature and electrical noise. For electrical noise, it is recommended to install the module away from AC or high level DC voltage. In addition, it is best to install this module away from the system power supply. The chassis closest to the bottom of the cabinet is recommended for ambient temperature.

The module cannot be removed when powered on. Do not remove the module while it is powered on, as electrical arcs may cause damage to electronic circuits. The module can also be installed via a removable terminal board (RTB) mounted on its front panel. Use 14 AWG wires and limit a maximum of two (2) wires to the same terminal. This is to provide room for troubleshooting and to be able to close the module cover.

The analog output can be assigned to the PID controller output, the result of a mathematical operation, or a manual value input from the human-machine interface (HMI) or monitoring and Data acquisition (SCADA). These are the control command sources. It can also be used to forward signals for reference by other devices to realize their monitoring, recording and conversion applications. For independent controllers that require control coordination, such as load sharing functions, the analog output can be used to send reference signals for all relevant controllers and devices.

This article is from the official website of Zhangzhou Branch of Xiamen Xiongba E-commerce Co., LTD. Please attach this link: http://www.sauldcs.com/

1746-NO4V

Please contact Sunny

Sales Manager: Sunny

QQ:3095989363

Mobile phone/wechat number: +86-18059884797

Email :sales@xiongbagk.cn

You May interest:

PHOENIX ILB BT ADIO 2/2/16/16 MAC 6313D-361-PM-504DA+PME504DAAG GE RS-FS-9001
KEBA SI485/422  21809 KONGSBERG MRU-M-MB3 ABB CI860K01 3BSE032444R1
BENTLY 3500/15 LYNGSO MARINE AEM402 ABB 216NG61A HESG441633R1 HESG216875/K
TRICONEX 3704E ABB V17152-310 ENTERASYS A4H254-8F8T P0973JP
TRICONEX 3504E MTL 8202-HO-IS Vibro-meter VM600 IOC4T
BENTLY 3500/42 ABB 3BHE009017R0102 Vibro-meter VM600 IOC16T
Vibro-meter VM600 RPS6U STUCK SYMAP-BCG MTL 8220-DI-IS
MTS TBF120/7R VIPA 62K-NHC0-DH EATON XVS-440-10MPI-1-10
ABB 1TGE120028R0010 GE 5KCP39PG PHOENIX ILB BT ADIO 2/2/16/16
ABB SPAU140C HONEYWELL 10302/1/1 ABB 3BHE009017R0102
SHINKAWA VM-5G0-2 ENTERASYS A4H124-24TX P0973JM Vibro-meter VM600 IOC4T
KONGSBERG RCU502 MTL 8724-CA-PS ABB DDC779CE102 3BHE027859R0102
VAT 65040-PACV-AYU2 MTL 8622-FT-IS EMG SV1-10/48/315/6
ABB LDSYN-101 KOLLMORGEN RMP201-8 PHOENIX ILB BT ADIO 2/2/16/16
ABB PFEA111-65 3BSE028140R0065 REUTER-STOKES RS-FS-9001 362A1052P104 MTL 8920-PS-DC

About Shipping

  • We will deliver the goods within 1-5 working days after receiving the payment;
  • Please leave your phone number for on-time delivery;
  • We can ship these goods to all countries. However, if you are in an excluded location, please contact us to calculate the freight

About Shipping

Disclaimer of liability:

Zhangzhou Branch of Xiamen Xiongba E-commerce Co., LTD. We sell new products and discontinued products, independent channels to buy such special products. Xiamen Xiongba Electronic Commerce Co., LTD. Zhangzhou Branch is not an authorized distributor, distributor or representative of the featured products on this website. All product names/product images, trademarks, brands and logos used on this website are the property of their respective owners. Descriptions, descriptions or sales of products bearing these names, images, trademarks, brands and logos are for identification purposes only and do not imply any association with or authorization of any rights holder.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “1746-NO4V Allen-Bradley SLC 500 analog output module”

Your email address will not be published. Required fields are marked *

Post comment