MVAJ13D1GB0780A  Tripping and Control Relays

Protective relays are precise measuring devices, the contacts of which should not be expected to switch large electrical loads.
In some cases, the protective relay can trip a circuit- breaker directly, or according to the coil rating and the number of circuits to be energised.
The MVAJ relay interfaces with the protection to provide: higher contact capacity, additional contacts for tripping multiple circuit-breakers, control functions, signalling and
interlocking.

Category:

Description

MVAJ13D1GB0780A   Tripping and Control Relays

Protective relays are precise measuring devices, the contacts of which should not be expected to switch large electrical loads.
In some cases, the protective relay can trip a circuit- breaker directly, or according to the coil rating and the number of circuits to be energised.
The MVAJ relay interfaces with the protection to provide: higher contact capacity, additional contacts for tripping multiple circuit-breakers, control functions, signalling and
interlocking.
The MVAJ range comprises very reliable hinged armature relays designed to directly operate circuit-breaker trip coils. Built to very high specifications, the MVAJ range provides
a highly flexible and reliable link between the protective relays and the circuit-breakers.
Models Available
 Trip relays
Trip relays possess a standard hand-reset flag and operate within 10 ms.
Table 1 shows the trip relay versions available
 Control relays
Control relay variants of each trip relay are available. These relays operate within
approximately 15 ms
 All relays configured for high burden applications are suitable for DC operation only

MVAJ13D1GB0780A

Key Features
 Negligible contact bounce
 10 contacts in Midos size 2 case and 20 contacts in Midos size 4 case
 Supplied as high burden
 Low burden easily selectable by removing an external link
 Hand, electrical and self reset variations
 Reset inhibition feature
 Delayed cut-off available in high burden applications
 AC or DC operation for low burden configuration
 2.5 second time delay
Key Benefits
 Directly operates circuit breaker trip coils
 High reliability
 High-speed operation
 Immunity to wiring capacitance discharge

Self-reset relays reset when the initiating signal is removed, making them suitable for use as trip relays in auto-reclose
schemes and also for general flagging purposes. Hand-reset relays require manual resetting, making them effective lockout relays
which are commonly used to trip circuit-breakers associated with transformers. Electrical-reset relays require a voltage to be
applied to the unit to reset the contacts. These relays may be used in auto-reclose schemes, or where remote resetting of the
relay is required.
Trip Relay
With the exception of the MVAJ 102 time delayed self-reset relays, all trip relays are suitable for either low burden or high burden applications.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “MVAJ13D1GB0780A  Tripping and Control Relays”

Your email address will not be published. Required fields are marked *

Post comment