Description
PROCESSOR 958481321300 PSB Function module
The arithmetic machine is the part of the computer which carries out various arithmetic and logic operation, among which the arithmetic logic unit is the part of the central processing core.
(1) Arithmetic logic Unit (ALU). Arithmetic logic unit is a combinatorial logic circuit which can realize multiple groups of arithmetic operations and logic operations. It is an important part of central processing. Arithmetic logic unit operations are mainly to carry out binary arithmetic operations, such as addition, subtraction, multiplication. In the operation process, the arithmetic logic unit mainly executes arithmetic and logic operations based on the instruction set of the computer. Generally speaking, ALU can play the role of reading in and reading out directly, which is embodied in the processor controller, memory and input/output devices, etc. Input/output is implemented on the basis of the bus. An input instruction contains an instruction word, including an operation code, a format code, and so on.
(2) Intermediate register (IR). Its length is 128 bits, and its actual length is determined by its operand. IR plays an important role in the “stack and fetch” instruction. During the execution of this instruction, the contents of ACC are sent to IR, and then the operand is fetched to ACC, and the contents of IR are pushed into stack.
(3) arithmetic accumulator (ACC). Current registers are generally single accumulators with a length of 128 bits. For ACC, think of it as a variable-length accumulator. In the description of instructions, the expression of ACC length is generally based on the value of ACS, and ACS length is directly related to ACC length. Doubling or halving the length of ACS can also be regarded as doubling or halving the length of ACC.
(4) Description word register (DR). It is mainly used to store and modify description words. The length of DR Is 64 bits. In order to simplify data structure processing, the use of descriptors plays an important role.
(5) Register B. It plays an important role in the instruction modification. The length of B register is 32 bits, which can save the address modification during the address modification process. The main memory address can only be modified with description words. The first element that points to the array is the descriptor, so accessing other elements in the array should require modifications. For number composition, it is composed of data or elements of the same size and stored continuously. The common access method is vector descriptor word, because the address in vector descriptor word is byte address. Therefore, in the conversion process, the basic address should be added first. For conversion work, mainly by hardware automatic implementation, in this process to pay special attention to alignment, so as not to go out of the array bounds.
This article is from the official website of Zhangzhou Branch of Xiamen Xiongba E-commerce Co., LTD. Please attach this link: http://www.sauldcs.com/
Sales Manager: Sunny
QQ:3095989363
Mobile phone/wechat number: +86-18059884797
Email :sales@xiongbagk.cn
You May interest:
PHOENIX ILB BT ADIO 2/2/16/16 | MAC 6313D-361-PM-504DA+PME504DAAG | GE RS-FS-9001 |
KEBA SI485/422 21809 | KONGSBERG MRU-M-MB3 | ABB CI860K01 3BSE032444R1 |
BENTLY 3500/15 | LYNGSO MARINE AEM402 | ABB 216NG61A HESG441633R1 HESG216875/K |
TRICONEX 3704E | ABB V17152-310 | ENTERASYS A4H254-8F8T P0973JP |
TRICONEX 3504E | MTL 8202-HO-IS | Vibro-meter VM600 IOC4T |
BENTLY 3500/42 | ABB 3BHE009017R0102 | Vibro-meter VM600 IOC16T |
Vibro-meter VM600 RPS6U | STUCK SYMAP-BCG | MTL 8220-DI-IS |
MTS TBF120/7R | VIPA 62K-NHC0-DH | EATON XVS-440-10MPI-1-10 |
ABB 1TGE120028R0010 | GE 5KCP39PG | PHOENIX ILB BT ADIO 2/2/16/16 |
ABB SPAU140C | HONEYWELL 10302/1/1 | ABB 3BHE009017R0102 |
SHINKAWA VM-5G0-2 | ENTERASYS A4H124-24TX P0973JM | Vibro-meter VM600 IOC4T |
KONGSBERG RCU502 | MTL 8724-CA-PS | ABB DDC779CE102 3BHE027859R0102 |
VAT 65040-PACV-AYU2 | MTL 8622-FT-IS | EMG SV1-10/48/315/6 |
ABB LDSYN-101 | KOLLMORGEN RMP201-8 | PHOENIX ILB BT ADIO 2/2/16/16 |
ABB PFEA111-65 3BSE028140R0065 | REUTER-STOKES RS-FS-9001 362A1052P104 | MTL 8920-PS-DC |
About Shipping
- We will deliver the goods within 1-5 working days after receiving the payment;
- Please leave your phone number for on-time delivery;
- We can ship these goods to all countries. However, if you are in an excluded location, please contact us to calculate the freight
Disclaimer of liability:
Zhangzhou Branch of Xiamen Xiongba E-commerce Co., LTD. We sell new products and discontinued products, independent channels to buy such special products. Xiamen Xiongba Electronic Commerce Co., LTD. Zhangzhou Branch is not an authorized distributor, distributor or representative of the featured products on this website. All product names/product images, trademarks, brands and logos used on this website are the property of their respective owners. Descriptions, descriptions or sales of products bearing these names, images, trademarks, brands and logos are for identification purposes only and do not imply any association with or authorization of any rights holder.
Please contact Sunny sales@xiongbagk.cn for the best price.
➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com
Reviews
There are no reviews yet.