8V1045.00-2 ACOPOS servo drive

DESCRIPTION:
  • Modular mechanical design using plug-in modules
  • Integrated line filter
  • Integrated braking resistor
  • All connections are made using plug-in connectors
  • Integrated electronic restart inhibit

ACOPOS servo drive, 3x 400-480 V, 4.4 A, 2 kW, integrated line filter, braking resistor and electronic safe restart interlock

Category:

Description

8V1045.00-2 ACOPOS servo drive

MATERIAL NUMBER:

8V1045.00-2

DESCRIPTION:
  • Modular mechanical design using plug-in modules
  • Integrated line filter
  • Integrated braking resistor
  • All connections are made using plug-in connectors
  • Integrated electronic restart inhibit

ACOPOS servo drive, 3x 400-480 V, 4.4 A, 2 kW, integrated line filter, braking resistor and electronic safe restart interlock

8V1045.00-2

• Modular mechanical design using plug-in modules
• Integrated line filter
• Integrated braking resistor
• All connections are made using plug-in connectors
• Integrated electronic restart inhibit

1) In the USA, TT and TN power mains are commonly referred to as “Delta/Wye with grounded Wye neutral”.
2) If the module is operated with a mains input voltage of 3x 230 VAC, then automatic nominal voltage detection doesn’t work for the DC bus. The UDC_NOMINAL
parameter must be set to 325 [V] by the user in this case.
3) Limit values from EN 61800-3 C3 (second environment).
4) The permissible input voltage range is reduced when using motor holding brakes. The input voltage range should be selected so that the proper supply
voltage for the motor holding brake can be maintained.
5) The current consumption depends on the configuration of the ACOPOS servo drive.
6) Valid in the following conditions: 400 VAC mains input voltage, nominal switching frequency, 40°C ambient temperature, installation elevation <500 m above
sea level.
7) Value for the nominal switching frequency.
8) If necessary, the stress of the motor isolation system can be reduced by an additional externally wired dv/dt choke. For example, the RWK 305 three-phase
dv/dt choke from Schaffner (www.schaffner.com) can be used. Important: Even when using a dv/dt choke, it is necessary to ensure that an EMC-compatible,
low inductance shield connection is used!
9) The module’s electrical output frequency (SCTRL_SPEED_ACT * MOTOR_POLEPAIRS) is monitored to protect against dual use in accordance with EC
regulation 428/2009 | 3A225. If the electrical output frequency of the module exceeds the limit value of 598 Hz uninterrupted for more than 0.5 s, then the
current movement is aborted and error 6060 is output (Power element: Limit speed exceeded).
10) OSSD (open signal switching device) signals are used to monitor signal lines for short circuits and cross faults.
11) Continuous operation of ACOPOS servo drives at elevations ranging from 500 m to 2000 m above sea level is possible (taking the specified continuous
current reductions into consideration).
12) Continuous operation of ACOPOS servo drives at ambient temperatures ranging from 40°C to max. 55°C is possible (taking the specified continuous current
reductions into consideration), but this will result in a shorter service life.

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com

Reviews

There are no reviews yet.

Be the first to review “8V1045.00-2 ACOPOS servo drive”

Your email address will not be published. Required fields are marked *

Post comment