8237-1604 integrated overspeed protection Keys Per Module

Model 8237-1600 can be configured to work with any size turbine, as long as it is powered by

steam, gas, or water. Speed readouts for this over acceleration device are between 4 and 20 mA.

This model will safely shut down any size turbine if it begins to dangerously speed up. The panel

mount has a backplane structure making repairs and replacements easy. Model 8237-1600 can be

easily integrated into any turbine system, and it comes with Modbus communications. It’s equipped

with MPU detection in addition to acceleration detection. The coating of this product makes it resistant

to sulfur contamination, and it can be used in class 3C2 environments. It has IEC 721-3-3 1994 international standards.

Category:

Description

8237-1604 integrated overspeed protection Keys Per Module

8237-1600 Technical Specifications

Dimensions 13 x 17.5 x 6.25 (inches)
Enclosure Type IP56 dust and water resistant (Installed properly)
Features Overvoltage protection II (per IEC 60664-1)
Input Voltage 2 High Voltage Inputs OR 1 High Voltage and 1 Low Voltage
Inrush Current 10 A at 115 Vac, 20 A @ 220 Vac
Keypad/Display 4.2in display and 15 Keys Per Module
Operating Temperature –20 to +60 °C at 95% humidity
Storage Temperature –20 to +65 °C at 95% humidity
Weight Less than 23 lbs

Product Description

Model 8237-1600 can be configured to work with any size turbine, as long as it is powered by

steam, gas, or water. Speed readouts for this over acceleration device are between 4 and 20 mA.

This model will safely shut down any size turbine if it begins to dangerously speed up. The panel

mount has a backplane structure making repairs and replacements easy. Model 8237-1600 can be

easily integrated into any turbine system, and it comes with Modbus communications. It’s equipped

with MPU detection in addition to acceleration detection. The coating of this product makes it resistant

to sulfur contamination, and it can be used in class 3C2 environments. It has IEC 721-3-3 1994 international standards.

It uses three independent trip relays, and low and high voltage power inputs. Model 8237-1600 also

uses two out of three voted architecture. This over-speed detection device has a triple module design,

making repairs possible while the system is still online. One module can be worked on while the other

two are operating. Product 8237-1600 can also perform routine speed tests with an internal generator and frequency.

8237-1367

Programming

  • The ProTechTPS functions as a safety PLC, as it accepts 10 discrete or analog inputs per module
  • (30 total), and allows users to create custom safety/protection programs to safely protect site personnel
  • and equipment. Programmers are able to utilize typical logic and testing sequence routines to create their application-specific safety logic and tests.

On-Line Testing

  • Each ProTechTPS module can be tested manually from the module’s front panel, Modbus
  • communications port, or automatically via its auto-test routine function. The ProTechTPS allows
  • users to configure overspeed or custom-programmed tests to be performed manually or automatically
  • on a periodic basis. With these test routines, each module (A, B, C) is tested one at a time, and
  • either a successful test result is logged or, upon sensing a fault, the routine is halted and the sensed fault indicated/alarmed.

On-Line Repair

  • The ProTechTPS’s triple modular design allows users to easily replace one of its modules (A, B, C)
  • while the monitored equipment/turbine is on-line and operating normally. Ease of replacement is
  • enhanced by the unit’s backplane plug-and-operate structure, and its module-to-module learning function.

Trip, Alarm, & Overspeed Logs

  • The ProTechTPS log function logs (saves to memory) all trips, alarms, trip valve response times, and
  • overspeed events. The trip log function uses a scrolling buffer and records the last 50 sensed trip
  • or alarm events and the last 20 overspeed events to memory, with associated times. Each log file can
  • be viewed from the unit’s front panel, or downloaded to a computer via the ProTechTPS service
  • tool program. Each module utilizes nonvolatile memory to ensure that all logged events are saved, even on loss of power.

 

Please contact Sunny sales@xiongbagk.cn for the best price.

➱ sales manager: Sunny
➱ email mailto: sales@xiongbagk.cn
➱ Skype/WeChat: 18059884797
➱ phone/Whatsapp: + 86 18059884797
➱ QQ: 3095989363
➱ Website:www.sauldcs.com